A simplified screening method for short- and medium-chain chlorinated paraffins in food by gas chromatography-low resolution mass spectrometry.

A simplified screening method for short- and medium-chain chlorinated paraffins in food by gas chromatography-low resolution mass spectrometry.

McGrath, Thomas J;Poma, Giulia;Bombeke, Jasper;Covaci, Adrian;
journal of chromatography a 2020 Vol. 1631 pp. 461574
204
mcgrath2020ajournal

Abstract

This study evaluates the performance of a simplified screening method for short- and medium-chain chlorinated paraffins (SCCPs and MCCPs, respectively) based on gas chromatography-electron capture negative ionization/mass spectrometry (GC-ECNI/MS) analysis and chlorine content quantification. The response from different combinations of 'indicator' congener groups present in technical mixture standards were used within calibration calculations to test the hypothesis that ∑SCCPs and ∑MCCPs could be quantified with acceptable accuracy using only a subset of the commonly analysed C to C and Cl to Cl groups. Potential combinations were assessed with respect to calibration curve performance and accuracy of SCCP and MCCP analysis of spiked food samples (olive oil, salmon, pork sausage, breakfast cereal, cow's milk and lard). Based on these trials, a screening method which quantifies ∑SCCPs and ∑MCCPs using only congener groups with 6 and 8 chlorine atoms for each carbon chain length was proposed. Concentrations of SCCPs and MCCPs in triplicate analyses of spiked food samples calculated using the proposed screening method deviated by ≤ 25% for the vast majority of samples (maximum deviation 37%) from levels determined using all analysed congener groups. The mean trueness of the screening method as applied to each of the spiked food samples and lard samples from a previous European Union Reference Laboratory (EURL) interlaboratory study ranged from 65 to 110% for ∑SCCPs and 102 to 175% for ∑MCCPs. Relative standard deviations (RSDs) were ≤ 25% for all triplicate analyses and matrix specific LOQs ranged from 0.7 to 6 ng/g ww for ∑SCCPs and from 1.3 to 12 ng/g ww for ∑MCCPs. The proposed screening method has the potential to deliver substantial time savings in instrumental analysis and manual labour without greatly reducing the overall accuracy and sensitivity of SCCP and MCCP quantification.

Citation

ID: 181753
Ref Key: mcgrath2020ajournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
181753
Unique Identifier:
S0021-9673(20)30849-9
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet