Clinical and dosimetric impact of adaptive intensity-modulated radiotherapy in locally advanced head-and-neck cancer

Clinical and dosimetric impact of adaptive intensity-modulated radiotherapy in locally advanced head-and-neck cancer

Maheshwari;Guncha Maheshwari;Aditya Dhanawat;Harvindra S Kumar;Neeti Sharma;Shankar Lal Jakhar;
journal of cancer research and therapeutics 2020 Vol. 16 pp. 600-
300
maheshwari2020journalclinical

Abstract

Background: Radiotherapy in head-and-neck cancer (HNC) is a challenging task, and the anatomical alterations occurring during the course of intensity-modulated radiotherapy (IMRT) can be compensated by adaptive radiotherapy (ART) which utilizes repeat computed tomography (CT) scans during the treatment course for replanning. In this study, the clinical and dosimetric benefits of ART were compared with the conventional IMRT.Materials and Methods: Sixty patients with locally advanced HNC were randomized into two arms to receive IMRT up to a curative dose of 70 Gy with concurrent weekly chemotherapy and were prospectively analyzed between March 2018 and March 2019. Repeat CT scan was acquired after the 3rd week of radiation. Patients in the study arm underwent replanning, whereas those in the control arm continued with the first IMRT plan. Assessment was done weekly till the end of treatment and at 1, 3, and 6 months post IMRT for disease response and toxicities. Tumor volume reduction rate (TVRR) and dose reduction to organs at risk were also recorded.Results: Complete response was observed in 90% and 96.7% patients in the control and study arms, respectively, at the end of 6 months. Insignificant differences were found between the two arms in terms of toxicities. Xerostomia was statistically significantly higher in the control arm at 6 months (P = 0.01). TVRR was found to be 31.85%. Dose to spinal cord, ipsilateral, and contralateral parotid reduced by 4.3%, 6%, and 2.2%, respectively, with ART.Conclusion: Mid-treatment adaptive replanning can help in better target coverage and minimize toxicities in HNC patients.

Citation

ID: 113503
Ref Key: maheshwari2020journalclinical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
113503
Unique Identifier:
0973-1482
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet