The effect of bispectral index monitoring on cognitive performance following sedation for outpatient colonoscopy: a randomized controlled trial

The effect of bispectral index monitoring on cognitive performance following sedation for outpatient colonoscopy: a randomized controlled trial

Sargin, Mehmet;Uluer, Mehmet Selçuk;Şimşek, Barış;
são paulo medical journal 0000 pp. -
427
sargin0000theso

Abstract

ABSTRACT BACKGROUND: Bispectral index (BIS) monitoring can positively affect cognitive performance through decreasing the use of sedative agents. We aimed to evaluate the effect of BIS monitoring on early cognitive performance among patients undergoing sedation for colonoscopy. DESIGN AND SETTING: Randomized, controlled trial in a university hospital. METHODS: 100 patients were randomized into two groups. In the monitored group (n = 50), the depth of anesthesia was monitored using the BIS, and BIS scores were maintained between 60 and 80. In the usual care group (n = 50), BIS monitoring was not performed. To determine the patients’ baseline cognitive performance levels, the mini-mental state examination (MMSE), Trieger dot test (TDT) and clock drawing test (CDT) were used. The patients’ post-procedure cognitive performance levels were determined when they were classified as ready for discharge. RESULTS: The total volume (mg) of propofol used [median (range) IQR] in the sedation procedure was lower in the monitored group [100 (50-200) 100-140] than in the usual care group [150 (75-200) 100-200] (P < 0.001). The discharge scores [mean (SD)] using MMSE and CDT were higher in the monitored group [26 (3) and 3 (1), respectively] than in the usual care group [23 (3) and 2 (1), respectively] (P = 0.002 and P = 0.002, respectively). The discharge scores using TDT [mean (SD)] were lower in the monitored group [11 (7)] than in the usual care group [15 (11)] (P = 0.033). CONCLUSION: BIS monitoring among sedated patients was associated with lower propofol use and smaller decline in cognitive performance. CLINICAL TRIAL REGISTRATION: This trial was registered in the Australian New Zealand Clinical Trial Registry (ACTRN12617000134325).

Citation

ID: 108253
Ref Key: sargin0000theso
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
108253
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet