Description of a new technique for automatic sonographic measurement of variation of head-perineum distance and angle of progression during active phase of second stage of labor.

Description of a new technique for automatic sonographic measurement of variation of head-perineum distance and angle of progression during active phase of second stage of labor.

Angeli, L;Conversano, F;Dall'Asta, A;Volpe, N;Simone, M;Di Pasquo, E;Pignatelli, D;Schera, G L B;Di Paola, M;Ricciardi, P;Ferretti, A;Frusca, T;Casciaro, S;Ghi, T;
Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology 2020
272
angeli2020descriptionultrasound

Abstract

To evaluate the performance of a new ultrasound technique for the automatic assessment of the changes of the head-perineum distance (delta-HPD) and of the Angle of Progression (delta-AoP) during the active phase of the second stage of labour.Prospective observational cohort study including singleton term pregnancies with fetuses in cephalic presentation during the active phase of the second stage of labour. Using the transperineal approach, two short video clips of 10 sec each were recorded between the rest and the acme of two expulsive efforts to measure the AoP and the HDP. The clips were processed off-line and the changes of the two measurements (delta-HDP and delta-AoP) were calculated manually by experienced sonographers and using a new automatic system. The reliability of the algorithm was evaluated by comparing the automatic and the manual measurements, which were assumed as the reference gold standard.Overall, 27 women were included. A significant correlation between the results obtained through the automated and the manual reference methods was found for both parameters (Intra-CC = 0.97; Intra-CC =0.99). The values of the coefficient of determination (r = 0.98; r =0.98) and the low residual errors (root mean square error =1.2 mm; root mean square error = 1.5°) confirm the good accuracy provided by the algorithm. The Bland-Altman analysis showed a mean difference of 0.52 mm (limits of agreement, 2.10 mm) for the delta-HPD (p=0.034) and of 0.35° (limits of agreement, 2.83°) for the delta-AoP (p=0.39).The automatic assessment of delta-AoP and delta-HPD during pushing efforts is feasible. The automatic measurement of delta-AoP appears reliable when compared to gold standard measurement. This article is protected by copyright. All rights reserved.

Citation

ID: 78319
Ref Key: angeli2020descriptionultrasound
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
78319
Unique Identifier:
10.1002/uog.21963
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet