Image-domain deep learning denoising for low-dose chest CT on a single 128-slice CT platform: a retrospective image-quality assessment.

Yao, Kaiqing; Jiang, Xue; Lv, Liang; Li, Yang; Zhang, Guangpeng; Zhang, Zhiyuan; Zhang, Zhiwei; Li, Xinyou; Lv, Fajin
Frontiers in medicine 2026 Vol. 13 pp. 1888006
12
kaiqing2026imagedomain

Abstract

Image-domain deep learning denoising may provide a practical post-processing approach for improving low-dose chest CT image quality on scanners without native deep learning reconstruction. This retrospective study evaluated a vendor-independent image-domain denoising algorithm applied to low-dose chest CT on a single 128-slice CT platform and descriptively compared the resulting image-quality metrics with those obtained using a standard-dose iterative reconstruction protocol. This retrospective study included 198 patients who underwent unenhanced chest CT and were assigned to a low-dose CT group (LDCT,  = 99) or a standard-dose CT group (SDCT,  = 99) according to the clinical acquisition protocol. All images were reconstructed using sinogram-affirmed iterative reconstruction (SAFIRE). LDCT images were additionally processed with a vendor-independent image-domain deep learning denoising algorithm (AiR Denoising), generating low-dose AiR-denoised images (LD-AiR). Objective image quality was assessed using attenuation, image noise, signal-to-noise ratio, and contrast-to-noise ratio. Subjective image quality of the lung parenchyma and mediastinal soft tissue was independently evaluated by readers using a 5-point scale. Compared with low-dose SAFIRE (LD-SAFIRE), LD-AiR significantly reduced image noise and increased signal-to-noise ratio and contrast-to-noise ratio across all evaluated regions (all  < 0.05). Subjective image quality scores for both lung parenchyma and mediastinal soft tissue were also significantly higher with LD-AiR than with LD-SAFIRE (all  < 0.05). In the descriptive between-group comparison, the LDCT protocol was associated with an approximately 76% lower effective dose than the SDCT protocol. Most objective and subjective image-quality metrics of LD-AiR did not differ significantly from those of SD-SAFIRE; however, this comparison was based on different patient groups and should not be interpreted as evidence of equivalence or non-inferiority. On the evaluated CT platform, vendor-independent image-domain deep learning denoising improved objective and subjective image quality of low-dose chest CT compared with LD-SAFIRE. These findings suggest that image-domain denoising may have potential utility for image-quality improvement on CT systems without native deep learning reconstruction. Further prospective, within-subject, multicentre studies incorporating lesion-detectability and diagnostic-performance assessment are needed to clarify its clinical applicability.

Citation

ID: 284733
Ref Key: kaiqing2026imagedomain
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
284733
Unique Identifier:
10.3389/fmed.2026.1888006
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet