Application of Deep Learning Algorithm-Based Image Reconstruction in Improving Abdominal CT Image Quality in Adrenal and Renal Lesions Detection.

Tian, Jingyi; Yao, Hui; Cao, Cong; Zhang, Peng; Wang, Sijia; Kang, Mingyue; Cui, Huafeng; Wu, Su
radiology research and practice 2026 Vol. 2026 pp. 2214739
9
jingyi2026application

Abstract

To evaluate the performance of the Deep Learning reconstruction algorithm Precise Image (PI) in improving abdominal computed tomography (CT) image quality and its diagnostic efficacy for adrenal and renal lesions. A total of 191 patients who underwent abdominal CT scan were retrospectively enrolled. All image datasets were reconstructed into four sequences with a slice thickness of 1 mm: Filtered back projection (FBP), Iterative Reconstruction (iDose), PI Standard, and PI Smooth. We measured CT attenuation values and the standard deviation (SD) of adrenal glands, renal parenchyma, and intra-abdominal fat for each reconstruction group. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of adrenal and renal parenchyma were subsequently calculated. Two radiologists independently performed subjective assessments for overall image quality and diagnostic confidence for adrenal nodules and renal cysts using the Likert 5 and 4 scales, respectively. Inter-reader agreement was quantified via the Kappa test. Intergroup comparisons were conducted using the Kruskal-Wallis test with Bonferroni post hoc correction. A priori power analysis was performed to verify the adequacy of the sample size. Statistically significant intergroup differences were identified for all subjective evaluation metrics ( < 0.05). The image quality score increases sequentially from FBP to PI Smooth group, and PI Smooth group has the highest subjective score. There were significant differences in diagnostic confidence scores among all groups ( < 0.05). PI Smooth has the highest score. There were significant differences in CT values, SD values, SNR, and CNR of the adrenal glands and renal parenchyma among the four groups of reconstructed images ( < 0.05). SD values declined progressively from FBP to iDose and further to PI Smooth, while SNR and CNR increased in the same order. Post hoc power analysis demonstrated statistical power > 0.99 for all primary clinical endpoints, confirming robust and reproducible statistical findings. Compared with FBP and iDose, the PI reconstruction algorithm substantially improves abdominal CT image quality. PI Smooth delivers the highest diagnostic confidence for small lesions and renal cysts, providing robust quantitative and qualitative support for precise clinical evaluation.

Citation

ID: 284720
Ref Key: jingyi2026application
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
284720
Unique Identifier:
10.1155/rrp/2214739
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet