missing left main ostio-proximal coronary artery disease during angiography using tiger catheter

missing left main ostio-proximal coronary artery disease during angiography using tiger catheter

;Biswajit Majumder;Viral Tandel
asee annual conference proceedings 2016 Vol. 4 pp. 108-109
127
majumder2016heartmissing

Abstract

Coronary angiography by right radial artery route using Optitorque Tiger catheter is on the rise given the low rate of local complications and feasibility to perform it as a day-care procedure. We report here a case of coronary angiography performed using Optitorque Tiger catheter (5-French) which resulted in a diagnostic error, missing the ostio-proximal left main coronary artery disease which was later detected using EBU 3.5 guide catheter (7-French) while performing angioplasty.