a systematic review and meta-analysis of radiotherapy planning studies comparing multi leaf collimator designs

a systematic review and meta-analysis of radiotherapy planning studies comparing multi leaf collimator designs

;Marco Luzzara;Luigi Santoro;Kevin Brown
fiat justisia 2018 Vol. 5 pp. 88-92
265
luzzara2018physicsa

Abstract

Background and purpose: Several studies have investigated multi leaf collimator (MLC) leaf design. We performed a systematic review and meta-analysis of those studies to compare the impact of MLC leaf width used for different radiotherapy techniques. Materials and methods: We decided to focus on 2.5, 3.0 and 5.0 mm leaf width MLCs as it appeared to be the most contentious area from literature. We adopted Cochrane and PRISMA guidelines and computed the association between MLC leaf width and conformity index (CI) across the selected studies as pooled mean difference (PMD) with 95% confidence interval. Results: A total of 43 papers were selected from the literature search, of which ten compare MLC leaf width of 2.5 mm or 3.0 mm (MLC2.5 mm) versus 5.0 mm (MLC5 mm) in terms of CI. There was a slight, but significant, difference between MLC2.5 mm and MLC5 mm in favor of the former (mean difference −0.036; 95% confidence interval: −0.068 to −0.005). A subgroup analysis was performed by comparing techniques (intensity modulated radiation therapy vs conformal). In the intensity modulated radiation therapy (IMRT) subgroup, the difference between MLC2.5 mm and MLC5 mm appeared to be negligible (mean difference: −0.006; 95% confidence interval: −0.013 to 0.001) and not significantly different from zero. In the subgroup of studies which used conformal techniques, there was a significant difference between MLC2.5 mm and MLC5 mm (mean difference: −0.054; 95% confidence interval: −0.096 to −0.012). Conclusions: Introduction of IMRT produced comparable target coverage (CI) between 2.5 or 5.0 mm leaf width MLCs. Keywords: Multi leaf collimators, Treatment planning system, Intensity modulated radiation therapy, Systematic review, Meta-analysis

Citation

ID: 200052
Ref Key: luzzara2018physicsa
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
200052
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet