Adaptação de métodos semi-empíricos para estimar capacidade de carga de estacas de pequeno diâmetro no solo de Londrina, Estado do Paraná = Adaptation of the semi-empiric methods to calculate small diameter piles bearing capacity in the soil of Londrina City, Paraná State

Adaptação de métodos semi-empíricos para estimar capacidade de carga de estacas de pequeno diâmetro no solo de Londrina, Estado do Paraná = Adaptation of the semi-empiric methods to calculate small diameter piles bearing capacity in the soil of Londrina City, Paraná State

Miguel, Miriam Gonçalves;Silva, Daniel Fermino da;Campos, Gustavo Garcia Galego;Almeida, Maycon André de;Belincanta, Antonio;
acta scientiarum: technology 2005 Vol. 27 pp. 155-165
238
miguel2005adaptacoacta

Abstract

A cidade de Londrina, Estado do Paraná, possui um perfil geotécnicoconstituído de uma camada superficial de solo argilo-siltoso, poroso, laterítico e muitas vezes colapsível, que se estende até a profundidade máxima de 12 metros. As estacas utilizadas em obras de pequeno a médio porte se encontram totalmente embutidas nesta camada, sofrendo a influência de seu comportamento laterítico e colapsível. Os métodos clássicos brasileiros de estimativa de capacidade de carga de estacas tornam-se conservadores, frente aos resultados reais, quando aplicados em solos lateríticos e, contra a segurança, quando aplicados em solos colapsíveis, isto é, na condição crítica ao colapso. Este trabalho avalia os coeficientes de ajuste das resistências de ponta e ao atrito lateral para esses métodos, no caso de estacas apiloadas, sendo estes coeficientes obtidos pela retro-análise de resultados de provas de carga estática à compressão, realizadas no Campo Experimental de Engenharia Geotécnica da Universidade Estadual de Londrina.

The city of Londrina, Paraná, has a typical geotechnical profile defined by a superficial layer of porous silty clay with maximum depth of about 12 meters, that shows lateritic characteristics, andmany times, collapsibility. Casts in place piles are often used for small buildings in the region and are fully embedded in this soil layer. Therefore, this type of foundation is subjected to the lateritic and occasionally collapsible influence of soil. Brazilian pile bearing capacity methods may yield conservative results when applied to tropical soils, as far as the lateritic origin in concerned. On the other hand, it can be unsafe if collapsibility prevails. This paper evaluates coefficients to adjust both point and lateral resistance of cast in place small diameter piles in the situation described. The work was carried out at the Londrina State University Geotechnical Experimental Site, and back analysis from static compression load tests data was done.

Citation

ID: 99791
Ref Key: miguel2005adaptacoacta
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
99791
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet