Evaluation of Outcome Variability Associated With Lateral Wall, Mid-scalar, and Perimodiolar Electrode Arrays When Controlling for Preoperative Patient Characteristics.

Evaluation of Outcome Variability Associated With Lateral Wall, Mid-scalar, and Perimodiolar Electrode Arrays When Controlling for Preoperative Patient Characteristics.

Fabie, Joshua E;Keller, Robert G;Hatch, Jonathan L;Holcomb, Meredith A;Camposeo, Elizabeth L;Lambert, Paul R;Meyer, Ted A;McRackan, Theodore R;
otology & neurotology : official publication of the american otological society, american neurotology society [and] european academy of otology and neurotology 2018 Vol. 39 pp. 1122-1128
244
fabie2018evaluationotology

Abstract

Determine the impact of electrode array selection on audiometric performance when controlling for baseline patient characteristics.Retrospective evaluation of a prospective cochlear implant (CI) database (January 1, 2012-May 31, 2017).Tertiary Care University Hospital.Three hundred twenty-eight adult CI recipients.Hearing outcomes were measured through unaided/aided pure tone thresholds and speech recognition testing before and after cochlear implantation. All reported postoperative results were performed at least 6 months after CI activation. All device manufacturers were represented.Of the 328 patients, 234 received lateral wall (LW) arrays, 46 received perimodiolar (PM) arrays, and 48 received mid-scalar (MS) arrays. Patients receiving PM arrays had significantly poorer preoperative earphone and aided PTAs and SRTs, and aided Consonant-Nucleus-Consonant(CNC) word and AzBio +10 SNR scores compared with patients receiving LW arrays (all p ≤ 0.04), and poorer PTAs and AzBio +10 SNR scores compared with MS recipients (all p ≤ 0.02). No preoperative audiological variables were found to significantly differ between MS and LW patients. After controlling for preoperative residual hearing and speech recognition ability in a hierarchical multiple regression analysis, no statistically significant difference in audiological outcomes was detected (CNC words, AzBio quiet, or AzBio +10 SNR) among the three electrode array types (all p > 0.05).While previous studies have demonstrated superior postoperative speech recognition scores in LW electrode array recipients, these differences lose significance when controlling for baseline hearing and speech recognition ability. These data demonstrate the proclivity for implanting individuals with greater residual hearing with LW electrodes and its impact on postoperative results.

Citation

ID: 96451
Ref Key: fabie2018evaluationotology
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
96451
Unique Identifier:
10.1097/MAO.0000000000001951
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet