Ultra-performance liquid chromatography (UPLC) was investigated as a faster alternative to high-performance liquid chromatography (HPLC) for the simultaneous analysis of drugs usually prescribed in cardiovascular therapy. Upon a previously developed and validated solid phase extraction (SPE)-HPLC-photodiode array (PDA)-fluorescence (FLR) method, separation of chlorthalidone (CLTD; diuretic), valsartan and its metabolite (VAL and VAL-M1 respectively; angiotensin II receptor antagonist drugs) and fluvastatin (FLUV; statin) was performed in human plasma using an RP C18 column (50mmx2.1mm, 1.7microm, Waters Acquity UPLC (BEH)) and a tunable UV-vis (TUV) detector. After method transfer, different system variables were modulated to study the evolution of responses of the analytes and the endogenous interferences. The improved method was fully validated and the results were compared with its precursor HPLC method relating to analysis time, efficiency and sensitivity. The studied compounds were separated in less than 8min and the method showed good linearity (20-3000microg/L for chlorthalidone, 110-1100microg/L for valsartan-M1, 67-1900microg/L for valsartan and 48-1100microg/L for fluvastatin), precision and accuracy. The proposed method was found to be reproducible (RSD<10%), accurate (RE<15%), robust and suitable for quantitative analysis of the studied drugs in plasma obtained from patients under combined cardiovascular treatment.

Citation

ID: 96196
Ref Key: iriarte2009validationjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
96196
Unique Identifier:
10.1016/j.jchromb.2009.07.018
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet