Objective assessment of intraoperative tumor fluorescence reveals biological heterogeneity within glioblastomas: a biometric study.

Objective assessment of intraoperative tumor fluorescence reveals biological heterogeneity within glioblastomas: a biometric study.

Moiyadi, Aliasgar;Shetty, Prakash;Sridhar, Epari;Gota, Vikram;Gurjar, Murari;Saicharan, Ghantasala;Singh, Vikas;Srivastava, Sanjeeva;
journal of neuro-oncology 2020 Vol. 146 pp. 477-488
260
moiyadi2020objectivejournal

Abstract

Heterogeneity within GBMs and variability of visualized fluorescence combine to confer practical limitations to the technique of optical imaging. A biometric analysis was planned to objectively ascertain and analyse this phenomenon METHODS: 25 adult glioblastoma subjects undergoing resection were prospectively accrued. Biopsies were taken from various parts of the tumor and safe peritumoral zones. White light (WL) and visualized fluorescence was subjectively recorded. Corresponding histopathology [coalescent (C) or infiltrating (I) tumor] and protoporphyrin-IX (PPIX) levels were assayed.WL was very sensitive for detecting tumor. SF was more specific and had high positive predictive value for detecting tumor. WF on the other hand had a poor discriminatory efficacy. Mean PPIX levels were 3.0, 2.01 and 0.16 for SF, WF, and NF respectively. WF had a wide variable range of PPIX levels. Within the coalescent tumor areas, there was a variable distribution of fluorescence (both subjective as well as objective PPIX levels) with only 54% samples showing SF and high PPIX. In seven cases this discordance was noted within the same tumor (biological heterogeneity).Fluorescence may miss important tumor areas even if objective assessment is used. Histologically similar tumor areas may exhibit contrasting fluorescence properties, a phenomenon which needs further investigation and elucidation of underlying mechanisms which could potentially be manipulated to optimize the utility of fluorescence guidance.

Citation

ID: 92656
Ref Key: moiyadi2020objectivejournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
92656
Unique Identifier:
10.1007/s11060-019-03338-1
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet