Determination of total sulfur compounds and benzothiazole in asphalt fume samples by gas chromatography with sulfur chemiluminescence detection.

Determination of total sulfur compounds and benzothiazole in asphalt fume samples by gas chromatography with sulfur chemiluminescence detection.

Jaycox, L B;Olsen, L D;
applied occupational and environmental hygiene 2000 Vol. 15 pp. 695-704
198
jaycox2000determinationapplied

Abstract

As part of a collaborative project between the National Institute for Occupational Safety and Health and the Federal Highway Administration to evaluate asphalt pavers' exposures to asphalt fume and their potential health effects, a method was developed for the determination of total sulfur compounds and benzothiazole in asphalt fume samples. Asphalt fume samples were collected from asphalt mixtures with and without the addition of ground-up rubber tires. The asphalt fume samples were collected with sampling trains that consisted of a Teflon membrane filter and an XAD-2 adsorbent tube. Filter and sampling tube media were extracted with hexane and subsequently analyzed by gas chromatography with a sulfur chemiluminescence detector. Separation was achieved with a 100 percent dimethyl polysiloxane fused silica column. Typical calibration curves had linear correlation coefficients of 0.99 or better with a relative standard deviation (RSD) of 5 percent. Benzothiazole desorption efficiency (DE) determined using spiked sampling tubes ranged from 96.5 percent at 5.0 micrograms to 89.4 percent at 40 micrograms with RSD values from 0.9 to 4.0 percent. Benzothiazole storage recovery determined using sampling tubes spiked at 20 micrograms and refrigerated for 30 days at 4 degrees C was 89.8 percent when corrected for the DE with an RSD of 1.1 percent. The limit of detection for the method determined using spiked sampling tubes was 0.30 microgram. Quantitation for total sulfur compounds and benzothiazole was against benzothiazole standards in hexane. Because of detector selectivity, sample preparation consisted of a simple hexane extraction even when samples had a high background due to hydrocarbon overload. Detector sensitivity provided quantitation in the sub-microgram region. Because of the sample preparation step and because benzothiazole was determined during the same analysis run, this method is straightforward and analytically efficient. The method has been used to analyze asphalt fume samples collected at several asphalt paving and roof operations.

Access

Citation

ID: 86113
Ref Key: jaycox2000determinationapplied
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
86113
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet