Three-dimensional imaging of upper esophageal sphincter resting pressure.

Three-dimensional imaging of upper esophageal sphincter resting pressure.

Chitose, Shun-Ichi;Shin, Yasuro;Sato, Kiminori;Hamakawa, Sachiyo;Fukahori, Mioko;Ono, Takeharu;Umeno, Hirohito;
laryngoscope investigative otolaryngology 2019 Vol. 4 pp. 645-652
271
chitose2019threedimensionallaryngoscope

Abstract

High-resolution manometry (HRM) is used to analyze upper esophageal sphincter (UES) physiology. Conventional HRM can yield imprecise measurements of UES resting pressure given its unidirectional sensors and averaging of circumferential pressure. In contrast, three-dimensional (3D) measurements can yield precise UES resting pressure data over the entire length of the UES. This study conducted a detailed analysis of UES resting pressure as evaluated by 3D-HRM.Seventeen young, healthy adult participants (7 females and 10 males) were recruited. The 3D-HRM system used includes a pressure sensor catheter (outer diameter, 4 mm) and eight-channel transducers arranged circumferentially to acquire pressure data at 45° intervals. The catheter was inserted transnasally into the esophagus and automatically retracted at a speed of 1 mm/s. Participants performed the following tasks: maintain resting breathing, perform breath holding, and perform the Valsalva maneuver. Data were obtained and compared per millimeter over the longitudinal UES length.Clear 3D waveforms were identified, with greater mean UES pressures in anterior-posterior directions than in lateral directions ( < .05). The anterior distribution was located superior to the posterior portion. Significant differences were observed in mean UES pressures and UES resting integrals between resting breathing and the Valsalva maneuver ( < 0.05). No differences in functional UES length were observed.The normal UES resting pressure was not directionally uniform in the luminal structure. 3D-HRM imaging of UES resting pressure can help deepen our understanding of UES physiology.4.

Access

Citation

ID: 84054
Ref Key: chitose2019threedimensionallaryngoscope
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
84054
Unique Identifier:
10.1002/lio2.324
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet