Changes in high-resolution manometric diagnosis over time: implications for clinical decision-making.

Changes in high-resolution manometric diagnosis over time: implications for clinical decision-making.

Triadafilopoulos, George;Kamal, Afrin;Zikos, Thomas;Nguyen, Linda;Clarke, John O;
diseases of the esophagus : official journal of the international society for diseases of the esophagus 2020
179
triadafilopoulos2020changesdiseases

Abstract

Although High resolution esophageal manometry (HRM) is the gold standard to assess esophageal motility, little is known about the stability of the manometric diagnosis over time and its implications for management. To assess the stability and usefulness of repeat HRM in patients presenting with esophageal symptoms over time we performed this retrospective study of patients with esophageal symptoms. Medical records, questionnaires, and HRM tracing were independently reviewed using the Chicago classification. The primary objective was to assess the stability of the manometric diagnosis over time; secondary objective was its change (positive or negative). At least one repeat study was performed in 86 patients (36% women, ages 20-86, with mild to moderate symptoms), while 26 had a third procedure. Mean intervals between studies were 15 ± 1.6 months (for baseline v. first study) and 13 ± 0.8 months (for second to third study). Of the 27 patients initially with a normal study, 11 changed (five had esophago-gastric junction outflow obstruction [EGJOO], two diffuse esophageal spasm [DES], one jackhammer esophagus [JE], and three ineffective esophageal motility [IEM] [41% change]). Of the 24 patients with initial EGJOO, only nine retained it (65.2% change). Of nine patients with initial DES, four changed (44.4% change). Similarly, different diagnosis was seen in 7 of 24 initial IEM patients (22.7% change). Only one patient had achalasia initially and this remained stable. Additional changes were noted on a third HRM. Fluidity in the HRM diagnosis over time questions its validity at any timepoint and raises doubts about the need for intervention.

Access

Citation

ID: 84051
Ref Key: triadafilopoulos2020changesdiseases
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
84051
Unique Identifier:
doz094
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet