[Assistant diagnose for subclinical keratoconus by artificial intelligence].

[Assistant diagnose for subclinical keratoconus by artificial intelligence].

Zou, H H;Xu, J H;Zhang, L;Ji, S F;Wang, Y;
[zhonghua yan ke za zhi] chinese journal of ophthalmology 2019 Vol. 55 pp. 911-915
276
zou2019assistantzhonghua

Abstract

To investigate the diagnosis of normal cornea, subclinical keratoconus and keratoconus by artifical intelligence. Diagnostic study. From January 2016 to January 2019, who admitted to Tianjin Eye Hospital from 18 to 48 years old, with an average of (28.4±8.2) years of myopia patients in 2 018 cases. Two experienced ophthalmologists labeled keratoconus, subclinical keratconus and nomal cornea based on the topography. The data of 80% (1 615 cases) patients were randomly selected as the training set by computer random sampling method, and the data of 20% (403 cases) patients were used as the verification set. Using the Gradient Boosting Decision Tree (GBDT) algorithm to extract 28 corneal parameters, and establish an algorithm model to diagnose the corneal condition of the patient, verify the diagnostic accuracy of the model by using the 10-fold cross-validation method, and evaluate the model using the receiver operating characteristic curve. Sensitivity and specificity with the original labeling and ophthalmic resident labeling. The diagnostic accuracy of the model was 95.53%. The area under the receiver operating characteristic curve (AUC) of the validation set was 0.996 6. The accuracy of the model for diagnosis of subclinical keratoconus and normal cornea was 96.67%, the AUC of the validation set was 0.993 6; the accuracy of diagnosis of keratoconus and normal cornea was 98.91%, and the AUC of the validation set was 0.998 2. The diagnostic accuracy of the model is 95.53%, which is significantly better than the resident's 93.55%. The model established by artifical intelligence can diagnose the subclinical keratoconus with high accuracy, which can greatly improve the clinical diagnosis efficiency and accuracy of young and primary ophthalmologists. .

Citation

ID: 80493
Ref Key: zou2019assistantzhonghua
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
80493
Unique Identifier:
10.3760/cma.j.issn.0412-4081.2019.12.008
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet