A constant postpacing interval in response to overdrive pacing with variable number of beats: An aid in the identification of entrainment for a particular pacing train during macroreentrant atrial tachycardias.

A constant postpacing interval in response to overdrive pacing with variable number of beats: An aid in the identification of entrainment for a particular pacing train during macroreentrant atrial tachycardias.

Arceluz, Martín R;Barrio, Teresa;Castellanos, Eduardo;Salgado, Ricardo;García, Javier;Lázaro Rivera, Carla;Ortiz, Mercedes;Lucena Pardos, Irené;Almendral, Jesús;
journal of cardiovascular electrophysiology 2019 Vol. 30 pp. 2657-2667
230
arceluz2019ajournal

Abstract

When pacing trains with a constant cycle length (CL) but increasing number of beats are introduced during a macroreentrant atrial tachycardia (MAT), the postpacing interval (PPI) is expected to increase if entrainment does not occur but could be stable if entrainment occurs. We tested the ability of PPI analysis to detect entrainment.Synchronized pacing trains with increasing number of beats (1-20) were delivered from the coronary sinus (CS) and lateral right atrium (RA) at a CL 20 ms shorter than the MAT CL. Pacing trains were grouped in pairs differing by one-paced beat, and the ∆PPI measured.In an initial prospective cohort of 21 patients (48% had left atrial flutter) the mean ∆PPI was 21.3 ± 5.6 ms for pairs of pacing trains in which neither entrained the MAT and 2.8 ± 1.4 ms for those in which both entrained the MAT (P < .0001). Results were similar for common vs atypical flutter, PPI-TCL ≤30 ms vs PPI-TCL >30 ms, presence vs absence of antiarrhythmic drugs and faster vs slower MAT. When an index pacing train was compared to one with two-paced beats less, a PPI difference of <19 ms identified entrainment with 95% sensitivity and 98% specificity. In a validation cohort of 16 patients, this cut-off value resulted in sensitivity and specificity of 90% and 94%.A relatively constant ∆PPI in response to overdrive pacing with identical CL but different number of beats allows accurate discrimination between trains that entrained vs those which did not entrain a MAT.

Citation

ID: 79711
Ref Key: arceluz2019ajournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
79711
Unique Identifier:
10.1111/jce.14196
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet