"Comparative intra- and inter-rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer".

"Comparative intra- and inter-rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer".

Silva, Jordana B da;Sato, Tatiana O;Rocha, Ana P R;Driusso, Patricia;
neurourology and urodynamics 2019
313
silva2019comparativeneurourology

Abstract

Evaluate the intra- and inter-rater reliability of maximal voluntary contraction (MVC) of pelvic floor muscle (PFM) assessment by unidigital and bidigital vaginal palpation. As a secondary aim, evaluate the construct validity of vaginal palpation and a manometer.A total of 120 women were recruited and allocated into three groups according to age (group 1 [G1]: 18-35; G2: 36-59; G3: ≥60 years). Examiner A conducted an interview and examiners B and C performed evaluations of PFM function using both unidigital and bidigital vaginal palpation. Seven to 10 days later, examiner B repeated both types of vaginal palpation and measured the MVC pressure with a Peritron. Reliability was analyzed using Cohen's linear weighted Kappa (κ ). The construct validity was calculated using the Spearman's correlation (r ).Intra-rater reliability of unidigital and bidigital palpation was κ  = 0.75 and κ  = 0.58 in G1, κ  = 0.59 and κ  = 0.73 in G2, and κ  = 0.79 and κ  = 0.86 in G3, respectively. Inter-rater reliability of unidigital and bidigital palpation was κ  = 0.52 and κ  = 0.48 in G1, κ  = 0.47 and κ  = 0.52 in G2, and κ  = 0.50 and κ  = 0.64 in G3, respectively. Spearman's correlation coefficients were significant at r  = 0.79 and r  = 0.80 for unidigital and bidigital vaginal palpation, respectively.Unidigital or bidigital vaginal palpation were indicated to evaluate G1 and G2 but bidigital palpation was more reliable in G3 when two examiners performed the evaluation. For the assessment conducted by one examiner, unidigital palpation was more reliable in G1 while bidigital palpation was more reliable in G2 and G3. Both unidigital and bidigital palpation have high measures of validity.

Citation

ID: 74160
Ref Key: silva2019comparativeneurourology
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
74160
Unique Identifier:
10.1002/nau.24263
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet