Design and evaluation of an accurate CNR-guided small region iterative restoration-based tumor segmentation scheme for PET using both simulated and real heterogeneous tumors.

Design and evaluation of an accurate CNR-guided small region iterative restoration-based tumor segmentation scheme for PET using both simulated and real heterogeneous tumors.

Koç, Alpaslan;Güveniş, Albert;
Medical & biological engineering & computing 2019
299
koc2019designmedical

Abstract

Tumor delineation accuracy directly affects the effectiveness of radiotherapy. This study presents a methodology that minimizes potential errors during the automated segmentation of tumors in PET images. Iterative blind deconvolution was implemented in a region of interest encompassing the tumor with the number of iterations determined from contrast-to-noise ratios. The active contour and random forest classification-based segmentation method was evaluated using three distinct image databases that included both synthetic and real heterogeneous tumors. Ground truths about tumor volumes were known precisely. The volumes of the tumors were in the range of 0.49-26.34 cm, 0.64-1.52 cm, and 40.38-203.84 cm respectively. Widely available software tools, namely, MATLAB, MIPAV, and ITK-SNAP were utilized. When using the active contour method, image restoration reduced mean errors in volumes estimation from 95.85 to 3.37%, from 815.63 to 17.45%, and from 32.61 to 6.80% for the three datasets. The accuracy gains were higher using datasets that include smaller tumors for which PVE is known to be more predominant. Computation time was reduced by a factor of about 10 in the smaller deconvolution region. Contrast-to-noise ratios were improved for all tumors in all data. The presented methodology has the potential to improve delineation accuracy in particular for smaller tumors at practically feasible computational times. Graphical abstract Evaluation of accurate lesion volumes using CNR-guided and ROI-based restoration method for PET images.

Citation

ID: 73446
Ref Key: koc2019designmedical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
73446
Unique Identifier:
10.1007/s11517-019-02094-8
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet