Body Surface Area Is Not a Reliable Predictor of Tracheal Tube Size in Children

Body Surface Area Is Not a Reliable Predictor of Tracheal Tube Size in Children

Uzumcugil, Filiz;Celebioglu, Emre Can;Ozkaragoz, Demet Basak;Yilbas, Aysun Ankay;Akca, Basak;Lotfinagsh, Nazgol;Celebioglu, Bilge;
clinical and experimental otorhinolaryngology 2018 Vol. 11 pp. 301-308
352
uzumcugil2018bodyclinical

Abstract

Objectives The age-based Cole formula has been employed for the estimation of endotracheal tube (ETT) size due to its ease of use, but may not appropriately consider growth rates among children. Child growth is assessed by calculating the body surface area (BSA). The association between the outer diameter of an appropriate uncuffed-endotrachealtube (ETT-OD) and the BSA values of patients at 24–96 months of age was our primary outcome. Methods Cole formula, BSA, age, height, weight and ultrasound measurement of subglottic-transverse-diameter were evaluated for correlations with correct uncuffed ETT-OD. The Cole formula, BSA, and ultrasound measurements were analyzed for estimation rates in all patients and age subgroups. The maximum allowed error for the estimation of ETT-OD was ≤0.3 mm. Patients’ tracheas were intubated with tubes chosen by Cole formula and correct ETT-OD values were determined using leak test. ETT exchange rates were recorded. Results One-hundred twenty-seven patients were analyzed for the determination of estimation rates. Thirteen patients aged ≥72 months were intubated with cuffed ETT-OD of 8.4 mm and were accepted to need uncuffed ETT-OD >8.4 mm in order to be included in estimation rates, but excluded from correlations for size analysis. One-hundred fourteen patients were analyzed for correlations between correct ETT-OD (determined by the leak test) and outcome parameters. Cole formula, ultrasonography, and BSA had similar correct estimation rates. All three parameters had higher underestimation rates as age increased. Conclusion. The Cole formula, BSA, and ultrasonography had similar estimation rates in patients aged ≥24 to ≤96 months. BSA had a correct estimation rate of 40.2% and may not be reliable in clinical practice to predict uncuffedETT-size.

Citation

ID: 68325
Ref Key: uzumcugil2018bodyclinical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
68325
Unique Identifier:
9e79a2499e61f66ad5f5e70a6ce1b532
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet