Individualized cardiac resynchronization therapy: current status

Individualized cardiac resynchronization therapy: current status

Martin H Ruwald;Niels E Bruun and
research reports in clinical cardiology 2014 Vol. 5 pp. 305-317
212
martin2014individualizedresearch

Abstract

Individualized cardiac resynchronization therapy: current status Martin H Ruwald,1,2 Niels E Bruun1,3 1Department of Cardiology, Gentofte Hospital, Hellerup, Denmark; 2Heart Research Follow-up Program, Division of Cardiology, University of Rochester Medical Center, Rochester, NY, USA; 3Clinical Institute, Aalborg University, Aalborg, Denmark Abstract: Cardiac resynchronization therapy (CRT) has shown a substantial reduction in heart failure patient morbidity and mortality, with improvement in quality of life as well as symptoms. The therapy is, however, limited to approximately 10%–15% of heart failure patients and, typically, 30% do not derive benefit from the device. For optimal outcomes with CRT, the correct selection of patients is of paramount importance. The first parameter is depressed left ventricular systolic function, and the second is a wide QRS complex. Different nuances among clinical trials have rendered guidelines pragmatic and compromising, but also conflicting and confusing. A large proportion of real-life CRTs are implanted in patients where the evidence for benefit is scarce or not present. Further, for optimal benefit, patients require evidence-directed medical therapy at maximal doses, effective placement of ventricular leads, and high biventricular pacing percentages, along with optimized atrioventricular (AV) and interventricular interval device programming. These items, as well as specific clinical characteristics, such as AV block and atrial fibrillation, in the context of CRT indications, are discussed. This review focuses on these issues to guide the clinician through guidelines, with an evidence-based update on the current status of CRT. Keywords: Cardiac resynchronization therapy, prognosis, review, biventricular pacing, guideline, indications 

Citation

ID: 6782
Ref Key: martin2014individualizedresearch
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
6782
Unique Identifier:
10.2147/RRCC.S50541
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet