Intravascular ultrasound-guided percutaneous coronary intervention in left main coronary bifurcation lesions: a review

Intravascular ultrasound-guided percutaneous coronary intervention in left main coronary bifurcation lesions: a review

Michael Jansen Sulaiman;Shao-Liang Chen and
research reports in clinical cardiology 2017 Vol. 8 pp. 49-59
425
michael2017intravascularresearch

Abstract

Intravascular ultrasound-guided percutaneous coronary intervention in left main coronary bifurcation lesions: a review Michael Jansen Sulaiman, Shao-Liang Chen Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, People’s Republic of China Abstract: Drug-eluting stent (DES) intervention is now emerging as an alternative approach for unprotected left main coronary artery (ULMCA) other than coronary artery bypass graft (CABG). Untreated left main (LM) coronary occlusion is always associated with poor prognosis and high mortality rate. Collective data from numerous worldwide registries and results from randomized Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) trial demonstrated that percutaneous coronary intervention (PCI) of ULMCA is a viable alternative in selected patient groups. Intravascular ultrasound (IVUS) provides valuable luminal and plaque details of coronary lesion, which enable precise lesion severity assessment compared to angiographic assessment. IVUS is important to assess intermediate lesion severity, optimizing stent deployment in complex lesions; therefore, reducing poststenting complication has been shown to improve acute procedural result and subsequent clinical outcomes. In the current review, we aimed to focus on the role of IVUS in LM coronary bifurcation lesions. Keywords: intravascular ultrasound, left main coronary artery, bifurcation, ostial lesion, mid-shaft lesion, crush techniques

Citation

ID: 6742
Ref Key: michael2017intravascularresearch
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
6742
Unique Identifier:
10.2147/RRCC.S140850
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet