ZIF-8-Assisted NaYF4:Yb,Tm@ZnO Converter with Exonuclease III-Powered DNA Walker for Near-Infrared Light Responsive Biosensor.

ZIF-8-Assisted NaYF4:Yb,Tm@ZnO Converter with Exonuclease III-Powered DNA Walker for Near-Infrared Light Responsive Biosensor.

Lv, Shuzhen;Zhang, Kangyao;Zhu, Ling;Tang, Dianping;
Analytical chemistry 2019
303
lv2019zif8assistedanalytical

Abstract

This work reports a ZIF-8 (ZIF: Zeolitic Imidazolate Framework)-assisted NaYF4:Yb,Tm@ZnO upconverter for the photoelectrochemical (PEC) biosensing of carcinoembryonic antigen (CEA) under near-infrared (NIR) irradiation on a homemade 3D-printing device with DNA walker-based amplification strategy. The composite photosensitive material NaYF4:Yb,Tm@ZnO, as converter to transfer NIR import to photocurrent output, was driven from annealed NaYF4:Yb,Tm@ZIF-8. Yb3+ and Tm3+-codoped NaYF4 (NaYF4:Yb,Tm) converted NIR excitation into UV emission, matching with the absorption of ZnO for in-situ excitation to generate the photocurrent. Upon target CEA introduction, the swing arm of DNA walker including the sequence of CEA aptamer carried out the sandwiched bioassembly with CEA capture aptamer on the G-rich anchorage DNA tracks-functionalized magnetic beads. Thereafter, DNA walker was triggered, and the swing arm DNA was captured by the G-rich anchorage DNA according to partly complementary pairing and Exonuclease III (Exo III) consumed anchorage DNA by a burnt-bridge mechanism to go into the next cycle. The released guanine (G) bases from DNA walker enhanced the photocurrent response on a miniature homemade 3D-printing device consisting of the detection cell, dark box and light platform. Under optimal conditions, NaYF4:Yb,Tm@ZnO-based NIR light-driven PEC biosensor presented high sensitivity and selectivity for CEA sensing with a detection limit of 0.032 ng mL-1. Importantly, our strategy provides a new horizon for the development of NIR-based PEC biosensors in the aspect of developing MOF-derived photoelectric materials, flexible design of 3D-printing device and effective signal amplification mode.

Citation

ID: 67274
Ref Key: lv2019zif8assistedanalytical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
67274
Unique Identifier:
10.1021/acs.analchem.9b04710
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet