Transitioning to whole-body SPECT/CT in prostate cancer staging: a new concept for a better imaging workflow.

Transitioning to whole-body SPECT/CT in prostate cancer staging: a new concept for a better imaging workflow.

Weissinger, Matthias;Kupferschläger, Jürgen;La Fougère, Christian;Dittmann, Helmut;Fiz, Francesco;
nuklearmedizin nuclear medicine 2019
243
weissinger2019transitioningnuklearmedizin

Abstract

 Whole-body bone scan (BS) is the clinical standard in detecting bone metastases in prostate cancer patients. Additional SPECT/CT has allowed to significantly increase its diagnostic accuracy. However, performing both planar and additional SPECT/CT prolongs the total examination time and lowers patient throughput. In this study we aim to assess the diagnostic performance of a SPECT/CT-only protocol compared to the traditional procedure that is BS with a facultative SPECT/CT in case of unclear findings. 50 patients with high-risk prostate cancer and suspected bone metastases were enrolled in this retrospective study. All patients received a whole-body Tc-99m-DPD BS followed by a 3 field-of-view (FOV) SPECT/CT (GE Discovery 670 Pro) covering an area from the vertex to the mid-femur. Metastatic lesions were evaluated visually on BS and SPECT/CT and correlated to PSA-levels. Detection rate was up to 50 % higher in SPECT/CT than in BS (n = 2829 vs. n = 1942; p < 0.001), but 31/1942 (1.5 %) lesions detected on BS were located out of the SPECT/CT field-of-view. In our analysis a PSA-level of > 80 µg/l could be defined as a cut-off-value for metastatic spread beyond mid-thigh, as no patient with PSA< 80 µg/l had localizations outside the SPECT/CT field-of-view (AUCPSA = 0.95, p < 0.001 sensitivity: 100 %, specificity: 77 %, NPV: 100 %, PPV: 67 %). The SPECT/CT-only protocol did not prolong acquisition time significantly as compared to BS. In patients with high-risk prostate cancer presenting with PSA < 80 µg/l and absent clinical symptoms, vertex to mid-thighs 3-FOV-SPECT/CT was representative for the entire skeletal system and was able to detect more lesions than planar acquisition. This procedure did not prolong patient handling time significantly.

Citation

ID: 65009
Ref Key: weissinger2019transitioningnuklearmedizin
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
65009
Unique Identifier:
10.1055/a-1022-4115
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet