Differences between µCT-imaging and conventional CT for the diagnosis of possible diseases of the middle and inner cat ear.

Differences between µCT-imaging and conventional CT for the diagnosis of possible diseases of the middle and inner cat ear.

Beck, Tobias;Kilchling, Tim P;Meyer-Lindenberg, Andrea;
Anatomia, histologia, embryologia 2019 Vol. 48 pp. 268-276
203
beck2019differencesanatomia

Abstract

The aim of this study was to check the relevance of using in-vivo micro computed tomography (µCT) for the diagnosis of possible diseases of the middle and inner ear of the cat. Therefore, on the one hand, differences of the detail detectability between the two imaging methods conventional computed tomography (cCT) and in-vivo µCT were analyzed. Six healthy cat ears were dissected and scanned several times and the obtained images were compared with each other. On the other hand, histological slices of all ears were prepared and pictures of defined anatomical structures were taken and compared with the identical sectional plane of the µCT-images. This way it was possible to evaluate the quality and clinical limitations of the in-vivo µCT. The results show that an in-vivo µCT is suitable to analyze even the smallest osseous structures, such as the semicircular ducts, the spiral osseous lamina or the ossicles whereas with the help of cCT it is not possible to identify such small osseous structures because of their blurred and less detailed representation. Delicate soft tissue structures as the membranous labyrinth including hearing and vestibular organ cannot be differentiated with as well in-vivo µCT- as with cCT-images. In-vivo µCT represent a good possibility for more detailed diagnosis of extremely fine structures which cannot be detected with cCT. Histological slices can nonetheless not be replaced by in-vivo µCT due to a too low spatial resolution and the limitations of the in-vivo µCT with regard to the evaluation of soft tissue dense structures.

Citation

ID: 61435
Ref Key: beck2019differencesanatomia
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
61435
Unique Identifier:
10.1111/ahe.12438
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet