Underdosing of the maxillary sinus for small fields used in newer radiotherapy techniques: Comparison of thermoluminescent dosimeter and Monte Carlo data

Underdosing of the maxillary sinus for small fields used in newer radiotherapy techniques: Comparison of thermoluminescent dosimeter and Monte Carlo data

Singh, Navin;Sharma, Sunil Dutt;Painuly, Nirmal Kumar;Mandal, Abhijit;Agarwal, Lalit Mohan;Sinha, Ashutosh;
journal of cancer research and therapeutics 2018 Vol. 14 pp. 351-356
256
singh2018underdosingjournal

Abstract

Aims: To evaluate the underdosing of the maxillary sinus at its distal end produced by air cavity in the path of the 6 MV photon beam. Materials and Methods: A cubic solid water slab phantom of dimensions 18 cm × 18 cm × 18 cm with 4 cm × 4 cm × 4 cm air cavity 3 cm away from its anterior surface was used in this study. The percentage depth dose (PDD) for 6 MV X-rays along the central axis of the cubical air cavity was measured using thermoluminescent dosimeter-100 chips. The EGSnrc/DOSXYZnrc Monte Carlo (MC) code was used to estimate the PDD values in both homogeneous and inhomogeneous conditions. The dose data were generated for 1 cm × 1 cm, 2 cm × 2 cm, 3 cm × 3 cm, and 5 cm × 5 cm field sizes. Results: Average percentage dose reductions at 1 mm beyond the distal surface of the maxillary sinus for the field sizes 1 × 1, 2 × 2, and 3 × 3 cm2 are 42.4%, 39.5%, and 29.4%, respectively. However, for 5 cm × 5 cm field size, there is a dose enhancement (i.e., overdosing) at 1 mm from the distal surface of the maxillary sinus and the average percentage dose enhancement is 5.9%. Also, beyond 1 cm from the air-water interface, there is dose enhancement for all the field sizes. Conclusion: This study showed that the significant dose reduction occurs near the air-water interface for the treatment techniques using small photon fields such as intensity-modulated radiotherapy or other newer techniques. MC-based treatment planning calculation predicts realistic dose distribution while using small photon fields in the treatment of maxillary sinus.

Citation

ID: 57340
Ref Key: singh2018underdosingjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
57340
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet