Radiation interaction parameters for blood samples of breast cancer patients: an MCNP study.

Radiation interaction parameters for blood samples of breast cancer patients: an MCNP study.

Toker, Ozan;Caglar, Mustafa;Oz, Ersoy;Bakirdere, Sezgin;Topdagi, Omer;Eyecioglu, Onder;Icelli, Orhan;
radiation and environmental biophysics 2019 Vol. 58 pp. 531-537
229
toker2019radiationradiation

Abstract

The main goal of this study was to determine radiation interaction parameters such as mass attenuation coefficients, effective atomic numbers, and effective electron densities depending on element concentrations (Na, K, Cu, Zn, Al, Ca, Mg Cr, Fe, Se) in blood samples of patients with breast cancer. Eighty blood samples were collected and analyzed in this study (40 from breast cancer patients and 40 from healthy patients). The determination of element concentrations of the samples was performed with inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) after which the element concentrations were normalized to percentage. Mass attenuation coefficients were calculated by Monte Carlo simulation method. In addition, effective atomic numbers and effective electron density values of the blood samples were calculated with the ZXCOM program. One of the most important results of this study is that differences in radiation interaction parameters between the two groups were observed. More specifically, the mass attenuation coefficients of the healthy group's blood samples were higher than those of the cancerous group at photon energies of 50 keV, 100 keV, 250 keV and 500 keV, while they were lower at 1 MeV. All the MCNP results were consistent with the results obtained from ZXCOM. As the main result of this study it is concluded that photon atomic parameters such as mass attenuation coefficient, effective atomic number and electron density may be considered in cancer diagnosis or treatment modalities.

Citation

ID: 57129
Ref Key: toker2019radiationradiation
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
57129
Unique Identifier:
10.1007/s00411-019-00806-0
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet