Automatic detection of contouring errors using convolutional neural networks.

Automatic detection of contouring errors using convolutional neural networks.

Rhee, Dong Joo;Cardenas, Carlos E;Elhalawani, Hesham;McCarroll, Rachel;Zhang, Lifei;Yang, Jinzhong;Garden, Adam S;Peterson, Christine B;Beadle, Beth M;Court, Laurence E;
Medical physics 2019
227
rhee2019automaticmedical

Abstract

To develop a head and neck normal structures autocontouring tool that could be used to automatically detect the errors in autocontours from a clinically validated autocontouring tool.An autocontouring tool based on convolutional neural networks (CNN) was developed for 16 normal structures of the head and neck and tested to identify the contour errors from a clinically validated multiatlas-based autocontouring system (MACS). The computed tomography (CT) scans and clinical contours from 3495 patients were semiautomatically curated and used to train and validate the CNN-based autocontouring tool. The final accuracy of the tool was evaluated by calculating the Sørensen-Dice similarity coefficients (DSC) and Hausdorff distances between the automatically generated contours and physician-drawn contours on 174 internal and 24 external CT scans. Lastly, the CNN-based tool was evaluated on 60 patients' CT scans to investigate the possibility to detect contouring failures. The contouring failures on these patients were classified as either minor or major errors. The criteria to detect contouring errors were determined by analyzing the DSC between the CNN- and MACS-based contours under two independent scenarios: (a) contours with minor errors are clinically acceptable and (b) contours with minor errors are clinically unacceptable.The average DSC and Hausdorff distance of our CNN-based tool was 98.4%/1.23 cm for brain, 89.1%/0.42 cm for eyes, 86.8%/1.28 cm for mandible, 86.4%/0.88 cm for brainstem, 83.4%/0.71 cm for spinal cord, 82.7%/1.37 cm for parotids, 80.7%/1.08 cm for esophagus, 71.7%/0.39 cm for lenses, 68.6%/0.72 for optic nerves, 66.4%/0.46 cm for cochleas, and 40.7%/0.96 cm for optic chiasm. With the error detection tool, the proportions of the clinically unacceptable MACS contours that were correctly detected were 0.99/0.80 on average except for the optic chiasm, when contours with minor errors are clinically acceptable/unacceptable, respectively. The proportions of the clinically acceptable MACS contours that were correctly detected were 0.81/0.60 on average except for the optic chiasm, when contours with minor errors are clinically acceptable/unacceptable, respectively.Our CNN-based autocontouring tool performed well on both the publically available and the internal datasets. Furthermore, our results show that CNN-based algorithms are able to identify ill-defined contours from a clinically validated and used multiatlas-based autocontouring tool. Therefore, our CNN-based tool can effectively perform automatic verification of MACS contours.

Access

Citation

ID: 56578
Ref Key: rhee2019automaticmedical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
56578
Unique Identifier:
10.1002/mp.13814
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet