Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in COPD.

Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in COPD.

Milne, Stephen;Huvanandana, Jacqueline;Nguyen, Chinh;Duncan, Joseph M;Chapman, David G;Tonga, Katrina O;Zimmermann, Sabine C;Slattery, Alexander;King, Gregory G;Thamrin, Cindy;
journal of applied physiology (bethesda, md : 1985) 2019
276
milne2019timebasedjournal

Abstract

Pulmonary electrical impedance tomography (EIT) is a functional imaging technique which allows real-time monitoring of ventilation distribution. Ventilation heterogeneity (VH) is a characteristic feature of chronic obstructive pulmonary disease (COPD), and has previously been quantified using amplitude-based features derived from tidal variations in the amplitude of the EIT signal. However, VH may be better described by time-based metrics, the measurement of which is made possible by the high temporal resolution of EIT. We aimed to 1) quantify VH using novel time-based EIT metrics, and 2) determine the physiological relevance of these metrics by exploring their relationships with complex lung mechanics measured by the forced oscillation technique (FOT).We performed FOT, spirometry, and tidal-breathing EIT measurements in 11 healthy and 9 COPD volunteers. Through offline signal processing, we derived 3 features from the impedance-time (Z-t) curve for each image pixel: (1) t, mean expiratory time; (2) PHASE, mean time difference between pixel and global Z-t curves; and (3) AMP, mean amplitude of Z-t curve tidal variation. Distribution was quantified by the coefficient of variation (CV) and the heterogeneity index (HI).Both CV and HI of the tand PHASE features were significantly increased in COPD compared to controls, and both related to spirometry and FOT resistance and reactance measurements. In contrast, distribution of the AMP feature showed no relationships with lung mechanics.These novel time-based EIT metrics of VH reflect complex lung mechanics in COPD, and have the potential to allow real-time visualization of pulmonary physiology in spontaneously-breathing subjects.

Citation

ID: 55975
Ref Key: milne2019timebasedjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
55975
Unique Identifier:
10.1152/japplphysiol.00304.2019
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet