Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

Sommer, Bettina B;Weisenhorn, Martin;Ernst, Markus J;Meichtry, André;Rast, Fabian M;Kleger, Dominik;Schmid, Philipp;Lünenburger, Lars;Bauer, Christoph M;
journal of biomechanics 2019 pp. 109340
298
sommer2019concurrentjournal

Abstract

The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR to measure six degrees of freedom in a clinical setting. The aim of this study was to assess the validity and reliability of this system. The developed prototype consists of two infrared-emitting lighthouses and sensors, mounted on the participant's helmet and trunk belt, to detect the orientation of the head and trunk. The system was evaluated by means of an infrared light-reflecting marker tracking system. Twenty healthy participants, equipped with these sensors and markers, performed thirteen neck movement tasks. Linear and angular movements were measured. These tasks were repeated after six to eight days to assess test-retest reliability. Concurrent validity was assessed by the root mean square error, and reliability with generalizability theory. With an average root mean square error between 1.2 and 2.0° in angular and 0.4-0.5 cm in linear movements, the prototype was shown to precisely track these movements. Reliability of the prototype and the reference system was comparable for all tasks. A high contribution of participant's variability to the observed variance was generally detected, with the exception of joint repositioning error and upper cervical flexion. The reliability was task-specific and did not differ between the systems. The prototype system was shown to be valid, although the reliability of the repositioning and upper cervical flexion tests needs to be reconsidered.

Citation

ID: 55970
Ref Key: sommer2019concurrentjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
55970
Unique Identifier:
S0021-9290(19)30562-7
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet