Recomendações para se evitar grandes erros de dose em tratamentos radioterapêuticos Recommendations to avoid gross errors of dose in radiotherapeutic treatments

Recomendações para se evitar grandes erros de dose em tratamentos radioterapêuticos Recommendations to avoid gross errors of dose in radiotherapeutic treatments

Souza, Cleber Nogueira de;Monti, Carlos Roberto;Sibata, Cláudio Hissao;
radiologia brasileira 2001 Vol. 34 pp. 29-37
371
souza2001recomendacesradiologia

Abstract

Erros humanos são uma importante fonte de falhas em todos os passos do planejamento e do tratamento radioterapêutico. Com o objetivo de reduzir este grau de incerteza, várias organizações especializadas recomendam minuciosos programas de garantia da qualidade. No Brasil, programas deste tipo vêm tendo sua exigência intensificada, e a maioria dos serviços de radioterapia vem se orientando neste sentido, tanto em relação aos equipamentos de radiação e dosimetria, quanto em relação à verificação dos cálculos de dose em pacientes e das revisões das fichas de planejamento. Como uma contribuição a este esforço de qualidade, apresentam-se algumas recomendações para se evitar falhas de tratamento devidas a erros na dose de radiação recebida pelo paciente, como redundância nas verificações dos cálculos feitos manualmente ou por computador, e, também, a verificação da dose acumulada para cada paciente sob tratamento, semanalmente, além de se evitar a possibilidade de acesso a qualquer sistema de segurança do equipamento ao pessoal técnico treinado para apenas o operar. Além disso, deve-se considerar a possibilidade de se empregar um sistema computadorizado de verificação e registro do tratamento, dessa maneira prevenindo-se erros durante a aplicação diária devidos à seleção indevida dos diferentes parâmetros do tratamento. Reportam-se quatro incidentes radioativos recentes ocorridos no mundo, com injúrias em pacientes, e algumas ocorrências de erros grandes de dose.
Human mistakes are an important source of errors in radiotherapy and may occur at every step of the radiotherapeutic planning and treatment. To reduce this level of uncertainties, several specialized organizations have recommended a comprehensive quality assurance program. In Brazil, the requirement for these programs has been strongly stressed, and most radiotherapy services have pursued this goal regarding radiation units and dosimetry equipment, as well as the verification of the calculations of the patient's dose and the revision of the plan charts. As a contribution to the improvement of quality control, we present some recommendations to avoid failure of treatment due to error in the delivered dose, such as redundant check of the manual or computer calculations, weekly check of the total dose for each patient, and prevention of inadvertent access to any safety system of the equipment by any staff member that is only supposed to operate the machine. Moreover, the use of a computerized treatment record and verification system should be considered in order to eliminate errors due to incorrect selection of the treatment parameters, in a daily basis. We report four radioactive incidents with patient injuries occurred throughout the world and some gross errors of dose.

Citation

ID: 53365
Ref Key: souza2001recomendacesradiologia
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
53365
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet