Simultaneous determination of ten compounds in rat plasma by UPLC-MS/MS: Application in the pharmacokinetic study of Ma-Zi-Ren-Wan.

Simultaneous determination of ten compounds in rat plasma by UPLC-MS/MS: Application in the pharmacokinetic study of Ma-Zi-Ren-Wan.

Hu, Dong-Dong;Han, Quan-Bin;Zhong, Linda Li-Dan;Li, Yan-Hong;Lin, Cheng-Yuan;Ho, Hing-Man;Zhang, Man;Lin, Shu-Hai;Zhao, Ling;Huang, Tao;Mi, Hong;Tan, Hong-Sheng;Xu, Hong-Xi;Bian, Zhao-Xiang;
journal of chromatography b, analytical technologies in the biomedical and life sciences 2015 Vol. 1000 pp. 136-46
256
hu2015simultaneousjournal

Abstract

Ma-Zi-Ren-Wan (MZRW) is a classic Chinese formula which has been used to treat human constipation in China for over 2000 years. In order to make good and rational use of this formula in the future, this paper presents the first attempt to track the pharmacokinetic features of MZRW in rat using rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Ten chemical components of MZRW, namely, rhein, emodin, aloe emodin, hesperidin, naringin, amygdalin, albiflorin, paeoniflorin, magnolol and honokiol, were simultaneously determined in rat plasma after a single oral administration (10g/kg body weight) of MZRW to rats. Geniposide and liquiritin were used as internal standards. The separation was performed on a Waters ACQUITY BEH C18 column (100mm×2.1mm, 1.7μm). The detection was conducted by multiple-reaction monitoring (MRM) in negative ionization mode. Two highest abundant MRM transitions without interference were optimized for each analyte. This method was well validated in terms of linearity, precision, accuracy, recovery, matrix effect and stability. All calibration curves had good linearity (r(2)>0.995) over the concentration range from 3.9 to 125.0ng/mL for emodin, 3.9-500.0ng/mL for amygdalin, 2.0-4000.0ng/mL for naringin and hesperidin, 3.9-2000.0ng/mL for magnolol, 7.8-2000.0ng/mL for rhein and 3.9-4000.0ng/mL for albiflorin, paeoniflorin, aloe emodin and honokiol. The intra-day and inter-day precision (relative standard deviation) was within 15%, the accuracy (relative error) ranged from -13.6% to 15.1%, and the lower limit of quantification in plasma ranged between 2.0ng/mL and 7.8ng/mL. Extraction recovery, matrix effect and stability were satisfactory. The validated method was successfully applied to a pharmacokinetic study of these ten compounds after oral administration of MZRW to rats. The pharmacokinetic parameters of each compound can facilitate clinical studies in the future.

Citation

ID: 53314
Ref Key: hu2015simultaneousjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
53314
Unique Identifier:
10.1016/j.jchromb.2015.07.003
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet