Interpretation of in-air output ratio of wedged fields in different measurement conditions

Interpretation of in-air output ratio of wedged fields in different measurement conditions

Mehnati, Parinaz;Biglari, Farideh;Jomehzadeh, Ali;
journal of medical signals and sensors 2019 Vol. 9 pp. 117-122
268
mehnati2019interpretationjournal

Abstract

Background: The collimator scatter factor (Sc) is one of the most important parameters in monitor unit (MU) calculation. There are several factors that impact Scvalues, including head structures, backscatter in dose monitoring chambers, and wedges. The objective of this study was to investigate the variation of Scwith different buildup cap materials, wall thickness of buildup caps, source-to-chamber distances (SCDs), ionization chambers, and wedge angles in 6 MV photon beam. Methods: In this study, copper and Perspex buildup caps were made with two different thicknesses for each buildup cap. Measurements were performed on an Elekta Compact medical linear accelerator (6 MV) using RK dosimeter with a sensitive volume of 0.120 cm3 and Farmer-type ion chamber with a sensitive volume of 0.65 cm3. In all measurements, buildup caps and ionization chambers were positioned such as to stand vertically to the beam central axis. It was also investigated the effect of internal wedge with different angles (30° and 60°) different SCDs on Sc. Results: It was found in large field sizes, Scvalues in Perspex buildup cap were higher than copper. Different SCDs and type of ion chamber and wall thickness of buildup caps had no significant influence on Scvalues. The presence of wedge influenced Scvalues significantly. Variation of Scin wedged fields compared to open fields had a maximum deviation of 0.9% and 6.8% in 30° and 60° wedge angles, respectively. Conclusion: It was found that the presence of wedges had a significant influence on Scand increases with wedge angles. As such, it should be taken into account in manual MU calculations.

Citation

ID: 51351
Ref Key: mehnati2019interpretationjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
51351
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet