How reliable is perioperative anticoagulant management? Determining guideline compliance and practice variation by a retrospective patient record review.

How reliable is perioperative anticoagulant management? Determining guideline compliance and practice variation by a retrospective patient record review.

Moesker, Marco J;de Groot, Janke F;Damen, Nikki L;Huisman, Menno V;de Bruijne, Martine C;Wagner, Cordula;
BMJ open 2019 Vol. 9 pp. e029879
289
moesker2019howbmj

Abstract

Surgery in patients on anticoagulants requires careful monitoring and risk assessment to prevent harm. Required interruptions of anticoagulants and deciding whether to use bridging anticoagulation add further complexity. This process, known as perioperative anticoagulant management (PAM), is optimised by using guidelines. Optimal PAM prevents thromboembolic and bleeding complications. The purpose of this study was to assess the reliability of PAM practice in Dutch hospitals. Additionally, the variations between hospitals and different bridging dosages were studied.A multicentre retrospective patient record review.Records from 268 patients using vitamin-K antagonist (VKA) anticoagulants who underwent surgery in a representative random sample of 13 Dutch hospitals were reviewed, 259 were analysed.Our primary outcome measure was the reliability of PAM expressed as the percentage of patients receiving guideline compliant care. Seven PAM steps were included. Secondary outcome measures included different bridging dosages used and an analysis of practice variation on the hospital level.Preoperative compliance was lowest for timely VKA interruptions: 58.8% (95% CI 50.0% to 67.7%) and highest for timely preoperative assessments: 81% (95% CI 75.0% to 86.5%). Postoperative compliance was lowest for timely VKA restarts: 39.9% (95% CI 33.1% to 46.7%) and highest for the decision to apply bridging: 68.5% (95% CI 62.3% to 74.8%). Variation in compliance between hospitals was present for the timely preoperative assessment (range 41%-100%), international normalised ratio testing (range 21%-94%) and postoperative bridging (range 20%-88%). Subtherapeutic bridging was used in 50.5% of patients and increased with patients' weight.Unsatisfying compliance for most PAM steps, reflect suboptimal reliability of PAM. Furthermore, the hospital performance varied. This increases the risk for adverse events, warranting quality improvement. The development of process measures can help but will be complicated by the availability of a strong supporting evidence base and integrated care delivery regarding PAM.

Citation

ID: 5068
Ref Key: moesker2019howbmj
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
5068
Unique Identifier:
10.1136/bmjopen-2019-029879
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet