Are the Spanish baseline series markers sufficient to detect contact allergy to corticosteroids in Spain? A GEIDAC prospective study.

Are the Spanish baseline series markers sufficient to detect contact allergy to corticosteroids in Spain? A GEIDAC prospective study.

Mercader-García, Pedro;Pastor-Nieto, María A;García-Doval, Ignacio;Giménez-Arnau, Ana;González-Pérez, Ricardo;Fernández-Redondo, Virginia;Serra-Baldrich, Ester;Cordoba-Guijarro, Susana;Gatica-Ortega, María E;Silvestre-Salvador, Juan F;, ;
Contact dermatitis 2018 Vol. 78 pp. 76-82
278
mercadergarca2018arecontact

Abstract

Corticosteroids are among the most commonly used topical drugs. Contact allergy to these exists, but can be easily missed. Corticosteroid screening markers have been included in the baseline series with the aim of detecting most of the sensitized patients.To assess the prevalence of contact allergy to topical corticosteroids in Spain and examine the usefulness of corticosteroid markers to detect contact allergy to corticosteroids.In total, 3699 patients referred to 20 dermatology departments across Spain for patch testing with the baseline series, including budesonide and tixocortol pivalate, were also tested with six supplementary corticosteroids (methylprednisolone aceponate, mometasone furoate, prednicarbate, clobetasol propionate, betamethasone 17-valerate, and betamethasone 17,21-dipropionate). Additionally, 2547 (68.8%) patients were tested with hydrocortisone 17-butyrate.Fifty-four patients showed positive reactions to at least one of all tested corticosteroids (1.46%). Thirty-nine (1.05%) reacted to at least one of the additionally tested corticosteroids; among these, 24 of 39 (61.5%) did not react to any of the corticosteroid allergy screening markers tested.More than half of the patients who were allergic to the additionally tested corticosteroids were not detected with the corticosteroid allergy markers. An update of the corticosteroid allergy screening markers is encouraged, with consideration of group 3 corticosteroids.

Citation

ID: 47872
Ref Key: mercadergarca2018arecontact
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
47872
Unique Identifier:
10.1111/cod.12874
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet