Efficacy of halogen photopolymerization units in private dental offices in Toronto.

Efficacy of halogen photopolymerization units in private dental offices in Toronto.

El-Mowafy, Omar;El-Badrawy, Wafa;Lewis, Donald W;Shokati, Babak;Soliman, Osama;Kermalli, Jaffer;Encioiu, Avedus;Rajwani, Fatma;Zawi, Rema;
journal (canadian dental association) 2005 Vol. 71 pp. 587
285
elmowafy2005efficacyjournal

Abstract

Light units used for polymerization of resin composites are subject to deterioration with age, and frequent maintenance is required to maintain optimal efficacy. This study examined the efficacy of quartz-tungsten-halogen light units in private dental offices in Toronto for polymerization of resin composites.One hundred dental offices met all selection criteria and agreed to participate in the study. The light intensity was determined for a total of 214 light units. Disk-shaped specimens, 2.5 mm thick, were made from 2 resin composites (Charisma, Heraeus Kulzer; Point 4, Kerr Corp) and were subjected to photopolymerization: Charisma for 20 seconds (99 units) and Point 4 for 20 and 40 seconds (all 214 units). Knoop hardness values for the upper and lower surfaces of each specimen were determined, and relative hardness values (hardness of lower surface/hardness of upper surface x 100) were calculated. Data were analyzed using descriptive statistics, t-tests, 1-way analysis of variance, and simple and multiple linear regression (a = 0.05).The light intensity of the individual units varied widely, from 120 to 1,000 mW/cm2. Surface hardness and relative hardness were significantly (p < 0.05) and positively associated with light intensity, and wide ranges in surface hardness and relative hardness values were observed. Mean relative hardness ranged from 34.8% to 57.7%.Light polymerization units in private dental offices displayed a wide range in light intensity, and many had below-recommended levels. Of the resin composite specimens polymerized for 40 seconds with each of the 214 light units, only 10% reached the desired relative hardness of at least 80%. A positive linear relationship was found between light intensity and relative hardness. Increased exposure time resulted in a significant increase in relative hardness. Also, relative hardness was found to be dependent on the brand of composite material used. Dentists should regularly monitor the condition of light units and replace deteriorating parts.

Access

Citation

ID: 46576
Ref Key: elmowafy2005efficacyjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
46576
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet