Influence of physical assessment of different light-curing units on irradiance and composite microhardness top/bottom ratio.

Influence of physical assessment of different light-curing units on irradiance and composite microhardness top/bottom ratio.

Morimoto, Susana;Zanini, Renata Aló Maluza;Meira, Josete Barbosa Cruz;Agra, Carlos Martins;Calheiros, Fernanda Calabró;Nagase, Denis Yudi;
odontology 2016 Vol. 104 pp. 298-304
310
morimoto2016influenceodontology

Abstract

The aim of this study was to evaluate the influence of the physical assessment of different light-curing units from 55 dental offices on the irradiance and composite microhardness top/bottom ratio, and the influence of the radiometers for LED or QTH light sources on irradiance measurement. The irradiance of each light-curing unit was evaluated with two radiometers, either for LED or QTH light. A questionnaire regarding the type of source (LED or QTH), time of use, date of last maintenance and light-curing performance assessment applied. The physical assessments were evaluated regarding damage or debris on the light tip. For each light-curing unit, three composite specimens were made (diameter = 7 mm; thickness = 2 mm) with polymerizing time of 20 s, in order to perform the microhardness (Knoop) test. Data were analyzed by Kruskal-Wallis and Dunn test (α = 0.01). There was wide variation in irradiance (0-1000 mW/cm(2)). Approximately 50 % of the light-curing units presented radiation lower than 300 mW/cm(2); 10 % of light-curing units, especially those with LED source, presented values higher than 800 mW/cm(2), and 43 % of light-curing units worked with adequate irradiance between 301 and 800 mW/cm(2). In almost 60 % of cases, no maintenance of light-curing units was performed in a period of 3 to 10 years. The age of the light-curing units and the use of inadequate tips interfered negatively in irradiance. The data emphasize the importance of periodic maintenance of light-polymerizing, light-curing units.

Citation

ID: 46565
Ref Key: morimoto2016influenceodontology
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
46565
Unique Identifier:
10.1007/s10266-015-0229-y
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet