Evaluation of a deep learning-based pelvic synthetic CT generation technique for MRI-based prostate proton treatment planning.

Evaluation of a deep learning-based pelvic synthetic CT generation technique for MRI-based prostate proton treatment planning.

Liu, Yingzi;Lei, Yang;Wang, Yinan;Shafai-Erfani, Ghazal;Wang, Tonghe;Tian, Sibo;Patel, Pretesh;Jani, Ashesh B;McDonald, Mark;Curran, Walter J;Liu, Tian;Zhou, Jun;Yang, Xiaofeng;
Physics in medicine and biology 2019
216
liu2019evaluationphysics

Abstract

The purpose of this work is to validate the application of a deep learning-based method for pelvic synthetic CT (sCT) generation that can be used for prostate proton beam therapy treatment planning. We propose to integrate dense block minimization into 3D cycle-consistent generative adversarial networks (cycle GAN) framework to effectively learn the nonlinear mapping between MRI and CT pairs. A cohort of 17 patients with co-registered CT and MR pairs were used to test the deep learning-based sCT generation method by leave-one-out cross-validation. Image quality between the sCT and CT images, gamma analysis passing rate, dose-volume metrics, distal range displacement, and the individual pencil beam Bragg peak shift between sCT- and CT-based proton plans were evaluated. The average mean absolute error (MAE) was 51.32±16.91 HU. The relative differences of the statistics of the PTV dose volume histogram (DVH) metrics in between sCT and CT were generally less than 1%. Mean values of dose difference, absolute dose difference (in percent of prescribed dose) were -0.07±0.07% and 0.23±0.08%. Mean gamma analysis pass rate of 1mm/1%, 2mm/2%, 3mm/3% criteria with 10% dose threshold were 92.39±5.97%, 97.95±2.95% and 98.97±1.62% respectively. The median, mean and standard deviation of absolute maximum range differences were 0.09 cm and 0.23±0.25 cm. The median and mean Bragg peak shifts among the 17 patients were 0.09 cm and 0.18±0.07 cm. The image similarity, dosimetric and distal range agreement between sCT and original CT suggests the feasibility of further development of an MRI-only workflow for prostate proton radiotherapy.

Citation

ID: 41137
Ref Key: liu2019evaluationphysics
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
41137
Unique Identifier:
10.1088/1361-6560/ab41af
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet