The Effect of Piezoelectric Ultrasonic Scaler Tip Wear on Root Surface Roughness at Different Working Parameters: An Atomic Force Microscopic and Profilometric Study.

The Effect of Piezoelectric Ultrasonic Scaler Tip Wear on Root Surface Roughness at Different Working Parameters: An Atomic Force Microscopic and Profilometric Study.

Vengatachalapathi, Hariharasudhan;Naik, Rajesh;Rao, Rachana;Venugopal, Ranganath;Nichani, Ashish S;
journal of the international academy of periodontology 2017 Vol. 19 pp. 15-21
285
vengatachalapathi2017thejournal

Abstract

This study aimed to evaluate the influence of scaler tip wear and different working parameters, i.e., lateral force, power setting and tip angulation, on the roughness of root surfaces following treatment with piezoelectric ultrasonic scaling devices.Twenty piezoelectric ultrasonic scaler inserts (10 worn/10 new) were selected to examine the erosion ratio (ER) under atomic force microscopy (AFM). A total of 160 root samples were prepared and instrumented by new (n = 80) and worn inserts (n = 80) at different working parameters (tip angulation, power setting, lateral force). Roughness change (Rc) on root surfaces after instrumentation was examined by a contact profilometer.Statistically significant differences were found between the mean ERs of new and worn tips (p < 0.0001). The various combinations of the assessed working parameters showed synergistic effects resulting in a wide range of root surface roughness. The present study found the higher Rc in the group with a 45° angulation, (P10) high power setting and 1.0 N lateral force (subgroup 8) when compared to other groups. Among the groups, the worn scaler tips subgroup 8 showed a higher Rc (5.692 ± 0.81) when compared to new scaler tips subgroup 8 (4.798 ± 0.51; p < 0.001).The findings of the present study highlighted that scaler tip wear strongly influences the root surface roughness when used at higher tip angulation, lateral force and power settings. Hence, ultrasonic scaler tip wear should be periodically evaluated and should be considered as much as the other working parameters.

Access

Citation

ID: 37120
Ref Key: vengatachalapathi2017thejournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
37120
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet