Lead fixation in deep brain stimulation: comparison of three lead anchoring devices in China.

Lead fixation in deep brain stimulation: comparison of three lead anchoring devices in China.

Wang, Tao;Pan, Yixin;Zhang, Chencheng;Zhan, Shikun;Sun, Bomin;Li, Dianyou;
BMC surgery 2019 Vol. 19 pp. 92
287
wang2019leadbmc

Abstract

The accuracy of deep brain stimulation (DBS) depends on precise electrode positioning, which has been pursued for ideal treatment outcomes. As a critical component of DBS, the fixation performance of lead anchoring devices has been widely studied. Possible reasons for lead shift were analyzed in the current study and we further provided effective solutions to reduce potential manual errors.Seventy-nine patients who received DBS implantations at the Ruijin Hospital from April to November 2017 were retrospectively reviewed. Intraoperative lead shifts were measured by C-arm fluoroscopy. Lead adjustment counts were recorded and compared among three lead fixation devices: Stimloc™ (Medtronic, Minneapolis, MN, USA), TouchLoc (SceneRay, Suzhou, China), and the traditional lead anchoring device.Mean (± SD) distances of lead shifts were 0.29 ± 2.42 mm in Stimloc devices, 0.43 ± 0.55 mm in TouchLoc devices, and 1.52 ± 1.05 mm in traditional devices (p < 0.0001). Average numbers of adjustments in this series were 0.3 ± 0.5 in Stimloc devices, 0.3 ± 1.3 in TouchLoc devices, and 1.1 ± 1.0 in traditional devices (p = 0.0001). Pairwise comparisons among the three devices (TouchLoc vs. Stimloc: p = 0.273; TouchLoc vs. Traditional: p = 0.0001; Stimloc vs. traditional: p < 0.0001) suggested significant differences, which were mainly attributed to the traditional devices.Three lead anchoring devices have been compared for their performance in the accuracy of lead fixation, in which the newly designed lead fixation devices have presented its advantages to the traditional one. In addition to the application of the Stimloc and TouchLoc devices, verification by C-arm fluoroscopy should be performed to provide an intuitive view of the depth deviation of electrode position during DBS electrode implantation.

Citation

ID: 35773
Ref Key: wang2019leadbmc
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
35773
Unique Identifier:
10.1186/s12893-019-0558-9
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet