Clinical Evaluation of Portable Wound Volumetric Measurement Devices.

Clinical Evaluation of Portable Wound Volumetric Measurement Devices.

Chiang, Nathaniel;Rodda, Odette A;Kang, Anna;Sleigh, Jamie;Vasudevan, Thodur;
advances in skin & wound care 2018 Vol. 31 pp. 374-380
208
chiang2018clinicaladvances

Abstract

Wound dimensional assessments are important in determining the progress of a wound and the effect of interventions on wound healing. The FastSCAN (FS; Polhemus Inc, Colchester, Vermont) and Silhouette Mobile (SM; ARANZ Medical, Christchurch, New Zealand) are portable devices that quantify surface area, depth, and volume of wounds. This study evaluated their reliability in producing accurate wound measurements.This study was conducted at the Waikato Hospital, Hamilton, New Zealand.Eleven vascular patients with a combined total of 16 wounds underwent simultaneous wound measurements using three-dimensional computed tomography (CT) reconstruction, FS, and SM.The validity of FS and SM was tested against CT. Additionally, the interoperator reliability and intraoperator reliability of FS and SM were determined.The intraoperator reliability and interoperator reliability for volume recordings of the SM were 0.97 and 0.97, respectively, and for the FS were 0.96 and 0.97, respectively. The FS and SM measurements were not significantly different from CT. The SM consistently produced smaller wound volume and depth measurements compared with CT. In contrast, overestimation was observed for FS when compared with CT. However, the volume measurements in one wound were anomalous, being 10 times larger than CT measurements. Excluding this wound, there were strong correlations in wound volumes for SM and CT (r = 0.81; P ≤ .0001), for FS and CT (r = 0.99; P ≤ .001), and for SM and FS (r = 0.99; P ≤ .0001).Measurements from FS and SM were comparable to CT. Therefore, SM and FS devices both offer the benefit of being noncontact portable devices that produce reproducible and reliable readings.

Citation

ID: 33231
Ref Key: chiang2018clinicaladvances
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
33231
Unique Identifier:
10.1097/01.ASW.0000540072.52782.24
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet