Different cardiorespiratory effects of indoor air pollution intervention with ionization air purifier: Findings from a randomized, double-blind crossover study among school children in Beijing.

Different cardiorespiratory effects of indoor air pollution intervention with ionization air purifier: Findings from a randomized, double-blind crossover study among school children in Beijing.

Dong, Wei;Liu, Shan;Chu, Mengtian;Zhao, Bin;Yang, Di;Chen, Chen;Miller, Mark R;Loh, Miranda;Xu, Junhui;Chi, Rui;Yang, Xuan;Guo, Xinbiao;Deng, Furong;
Environmental pollution (Barking, Essex : 1987) 2019 Vol. 254 pp. 113054
248
dong2019differentenvironmental

Abstract

Indoor air pollution is associated with numerous adverse health outcomes. Air purifiers are widely used to reduce indoor air pollutants. Ionization air purifiers are becoming increasingly popular for their low power consumption and noise, yet its health effects remain unclear. This randomized, double-blind crossover study is conducted to explore the cardiorespiratory effects of ionization air purification among 44 children in Beijing. Real or sham purification was performed in classrooms for 5 weekdays. Size-fractionated particulate matter (PM), black carbon (BC), ozone (O), and negative air ions (NAI) were monitored, and cardiorespiratory functions were measured. Mixed-effect models were used to establish associations between exposures and health parameters. Real purification significantly decreased PM and BC, e.g. PM, PM, PM and BC were decreased by 48%, 44%, 34% and 50%, respectively. O levels were unchanged, while NAI was increased from 12 cm to 12,997 cm. Real purification was associated with a 4.4% increase in forced exhaled volume in 1 s (FEV) and a 14.7% decrease in fractional exhaled nitrogen oxide (FeNO). However, heart rate variability (HRV) was altered negatively. Interaction effects of NAI and PM were observed only on HRV, and alterations in HRV were greater with high NAI. Ionization air purifier could bring substantial respiratory benefits, however, the potential negative effects on HRV need further investigation.

Citation

ID: 31433
Ref Key: dong2019differentenvironmental
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
31433
Unique Identifier:
S0269-7491(19)32506-0
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet