IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Zabat, Mahdi;Ababou, Amina;Ababou, Noureddine;Dumas, Raphaël;
Medical & biological engineering & computing 2019
342
zabat2019imubasedmedical

Abstract

A lot of attention has been paid to wearable inertial sensors regarded as an alternative solution for outdoor human motion tracking. Relevant joint angles can only be calculated from anatomical orientations, but they are negatively impacted by soft tissue artifact (STA) defined as skin motion with respect to the underlying bone; the accuracy of measured joint angle during movement is affected by the ongoing misalignment of the sensor. In this work, a new sensor-to-segment calibration using inertial measurement units is proposed. Inspired by the multiple calibration for a cluster of skin markers, it consists in performing first multiple static postures of the upper limb in all anatomical planes. The movements that affect sensor alignment are identified then alignment differences between sensors and segment frames are calculated for each posture and linearly interpolated. Experimental measurements were carried out on a mechanical model and on a subject who performed different movements of right elbow and shoulder. Multiple calibration showed significant improvement in joint angle measurement on the mechanical model as well as on human joint angle comparing to those obtained from attached sensors after technical calibration. During shoulder internal-external rotation, the maximal error value decreased more than 50% after correction. Graphical abstract Elbow flexion-extension joint angle values obtained from IMUs are well-corrected after applying multiple calibration procedure. Though shoulder internal-external rotation joint angle is more affected by soft tissue artifact, multiple calibration procedure improves the angle values obtained from IMUs.

Citation

ID: 29410
Ref Key: zabat2019imubasedmedical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
29410
Unique Identifier:
10.1007/s11517-019-02033-7
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet