Accuracy of computer-assisted vertical cup-to-disk ratio grading for glaucoma screening.

Accuracy of computer-assisted vertical cup-to-disk ratio grading for glaucoma screening.

Snyder, Blake M;Nam, Sang Min;Khunsongkiet, Preeyanuch;Ausayakhun, Sakarin;Leeungurasatien, Thidarat;Leiter, Maxwell R;Sevastopolsky, Artem;Joye, Ashlin S;Berlinberg, Elyse J;Liu, Yingna;Ramirez, David A;Moe, Caitlin A;Ausayakhun, Somsanguan;Stamper, Robert L;Keenan, Jeremy D;
PloS one 2019 Vol. 14 pp. e0220362
223
snyder2019accuracyplos

Abstract

Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment.In this cross-sectional diagnostic accuracy study, 5 ophthalmologists independently assessed the VCDR from a set of 200 optic disk images, with the median grade used as the reference standard for subsequent analyses. Eight non-ophthalmologists graded each image by two different methods: by visual inspection and with assistance from a custom-made publicly available software program. Agreement with the reference standard grade was assessed for each method by calculating the intraclass correlation coefficient (ICC), and the sensitivity and specificity determined relative to a median ophthalmologist grade of ≥0.7.VCDR grades ranged from 0.1 to 0.9 for visual assessment and from 0.1 to 1.0 for software-assisted grading, with a median grade of 0.4 for each. Agreement between each of the 8 graders and the reference standard was higher for visual inspection (median ICC 0.65, interquartile range 0.57 to 0.82) than for software-assisted grading (median ICC 0.59, IQR 0.44 to 0.71); P = 0.02, Wilcoxon signed-rank test). Visual inspection and software assistance had similar sensitivity and specificity for detecting glaucomatous cupping.The computer software used in this study did not improve the reproducibility or validity of VCDR grading from fundus photographs compared with simple visual inspection. More clinical experience was correlated with higher agreement with the ophthalmologist VCDR reference standard.

Citation

ID: 29300
Ref Key: snyder2019accuracyplos
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
29300
Unique Identifier:
10.1371/journal.pone.0220362
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet