Cardiac perforation complicating cardiac electrophysiology procedures: value of angiography and use of a closure device to avoid cardiac surgery.

Cardiac perforation complicating cardiac electrophysiology procedures: value of angiography and use of a closure device to avoid cardiac surgery.

Shenthar, Jayaprakash;Singh, Balbir;Banavalikar, Bharatraj;Chakali, Siva Sankara;Delhaas, Tammo;Shivkumar, Kalyanam;Bradfield, Jason S;
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing 2020 Vol. 58 pp. 193-201
175
shenthar2020cardiacjournal

Abstract

Computed tomography (CT) is used for the diagnosis of cardiac perforation (CP) although it has significant limitations. We report our experience with angiography to assist in the diagnosis and management of cardiac perforation during electrophysiology procedures.Patients with suspected CP after pacemaker lead insertion (temporary = 2, permanent = 2) or during epicardial mapping/ablation (n = 2) were included. All patients underwent initial angiography with repeat study performed post-lead repositioning/withdrawal for the pacemaker cases. Patients with CP due to permanent pacing leads underwent CT comparison.In 4 pacemaker patients, temporary leads caused two acute perforations, permanent active fixation leads caused one subacute right ventricular perforation and one delayed right atrial perforation. CT overdiagnosed CP in one temporary pacemaker patient, and was non-diagnostic in an atrial lead perforation, whereas angiography was accurate in both. Angiography identified an active leak in atrial lead CP, guided percutaneous closure in one case and demonstrated sealing of perforation in all cases. In the 2 epicardial ablation cases, 1 patient underwent surgical repair after a persistent right ventricular perforation, but the other avoided surgery with novel use of an Amplazter® patent ductus arteriosus (PDA) closure device (Abbott, St Paul, MN, USA).Angiography may be more accurate than CT in the diagnosis of CP. Angiography is easy to perform, can be done acutely, reveals active leaks and can demonstrate sealing of perforations after percutaneous lead repositioning. Utilisation of a PDA closure device may avoid the need for surgery for RV perforation.

Citation

ID: 275448
Ref Key: shenthar2020cardiacjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
275448
Unique Identifier:
10.1007/s10840-019-00577-0
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet