Estimation of Left Ventricular Ejection Fraction by Semiautomated Edge Detection.

Estimation of Left Ventricular Ejection Fraction by Semiautomated Edge Detection.

Byron F. Vandenberg,Hiram Cardona,James G. Miller,Trudy L. Burns,David J. Skorton,Julio E. Pérez;Byron F. Vandenberg;Hiram Cardona;James G. Miller;Trudy L. Burns;David J. Skorton;Julio E. Pérez;
echocardiography 1998 Vol. 15 pp. 713-719
166
pérez1998echocardiographyestimation

Abstract

Left ventricular (LV) volume and ejection fraction estimation from two-dimensional echocardiograms requires off-line analysis and time-consuming manual tracing. LV volumes may be estimated on-line with a semiautomated edge detection echocardiographic system [also known as acoustic quantification (AQ)], but there are few data that compare volumes obtained from the AQ method with volumes derived from off-line manual tracing of conventional two-dimensional echocardiograms. Echocardiograms were performed in 48 patients at two medical centers. LV volumes were measured from the apical view with the method of discs and area-length formulae and from the parasternal short-axis view with the modified ellipsoid model. Based on the criterion of >/=75% endocardial visualization, 25 (52%) of the short-axis views and 14 (29%) of the apical views were analyzed by a single investigator. End-diastolic and end-systolic LV volumes derived on line with the AQ system showed a very strong linear association with off-line, manually traced volumes (r = 0.96-0.99). Correlations for ejection fraction also were strong (r = 0.90-0.96). End-diastolic and end-systolic LV volumes, measured from the apical views, were underestimated by the AQ method. However, because the error was in the same direction, ejection fractions measured with the AQ system and by manual tracing of conventional echocardiograms were similar. Estimation of ejection fraction using a semiautomated edge detection echocardiographic system is a promising method for noninvasive evaluation of systolic function in carefully selected patients.

Citation

ID: 268613
Ref Key: pérez1998echocardiographyestimation
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
268613
Unique Identifier:
10.1111/j.1540-8175.1998.tb00671.x
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet