Seth J. Berkowitz,Robson Macedo,Ashkan A. Malayeri,Steven M. Shea,Christine H. Lorenz,Hugh Calkins,Jens Vogel-Claussen,Harikrishna Tandri,David A. Bluemke;Seth J. Berkowitz;Robson Macedo;Ashkan A. Malayeri;Steven M. Shea;Christine H. Lorenz;Hugh Calkins;Jens Vogel-Claussen;Harikrishna Tandri;David A. Bluemke;
Magnetic resonance in medicine 2009 Vol. 61 pp. 307-314
165
bluemke2009magneticaxial

Abstract

Black blood turbo spin echo (TSE) imaging of the right ventricle (RV) free wall is highly sensitive to cardiac motion, frequently resulting in nondiagnostic images. Temporal and spatial parameters of a black blood TSE pulse sequence were evaluated for visualization of the RV free wall. Seventy‐four patient studies were retrospectively evaluated for the effects of acquisition timing on image quality. Axial black blood TSE images were acquired on 10 healthy volunteers to assess the role of spatial misregistration on right ventricle visualization; increasing the double inversion recovery (DIR) slice thickness beyond 300% had no effect on image quality (P = 0.2). Thirty‐five patient studies were prospectively evaluated with inversion times (TIs) corresponding to the mid‐diastolic rest period and end‐systole based on visual analysis of a four chamber cine. When TIs were chosen to be within the patients' RV rest period, mean image quality score was significantly improved (2.3 vs 1.86; P < 0.001) and the number of clinically diagnostic images increased from 32% to 46%. Black blood TSE imaging of the RV free wall is highly sensitive to cardiac motion. Image quality can be improved by choosing TIs concordant with the rest period of the patient's RV that may occur at mid‐diastole or end‐systole. Magn Reson Med 61:307–314, 2009.

Citation

ID: 267243
Ref Key: bluemke2009magneticaxial
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
267243
Unique Identifier:
10.1002/mrm.21864
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet