Effect of Instrument Design and Technique on the Precision and Accuracy of Objective Refraction Measurement

Effect of Instrument Design and Technique on the Precision and Accuracy of Objective Refraction Measurement

Alberto Domínguez-Vicent;Loujain Al-Soboh;Rune Brautaset;Abinaya Priya Venkataraman;Domínguez-Vicent, Alberto;Al-Soboh, Loujain;Brautaset, Rune;Venkataraman, Abinaya Priya;
journal of clinical medicine 2020 Vol. 9 pp. 3061-
167
domínguez-vicent2020journaleffect

Abstract

Background: To evaluate the precision and accuracy of objective refraction measurement obtained with combinations of instrument design and technique. We also compared the performance of the instruments with subjective refraction measurements. Method and analysis: The objective refraction was measured in 71 subjects with three autorefractometers that have different designs and measurement principles (binocular with fogging, binocular without fogging, and monocular with fogging). Repeatability and reproducibility metrics were calculated for the objective refraction measurements. The agreement of the objective refraction measurements between the three instruments and the agreement with the subjective refraction measurements were evaluated. Results: All three autorefractometers had repeatability and reproducibility limits smaller than 0.70D. The smallest difference (0.10D) in the spherical equivalent was seen between the two binocular instruments. Compared with the subjective refraction, the binocular without fogging technique had the smallest mean difference in spherical equivalent (<0.20D) whereas the binocular fogging technique had the smallest limit of agreement interval (1.00D). For all comparisons, the mean difference and limit of agreement interval for the cylindrical components were lower than 0.10D and 0.75D, respectively. Conclusion: All three instruments evaluated had good repeatability and reproducibility. The binocular fogging technique provided the best agreement with subjective refraction.

Citation

ID: 261504
Ref Key: domínguez-vicent2020journaleffect
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
261504
Unique Identifier:
10.3390/jcm9103061
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet