unsteady polar fluid model of blood flow through tapered ω-shape stenosed artery: effects of catheter and velocity slip

unsteady polar fluid model of blood flow through tapered ω-shape stenosed artery: effects of catheter and velocity slip

;D. Srikanth;J.V. Ramana Reddy;Shubha Jain;Anup Kale
der pharmacia lettre 2015 Vol. 6 pp. 1093-1104
211
srikanth2015ainunsteady

Abstract

In this paper, we considered the pulsatile flow of blood through catheterized tapered artery in the presence of an ω-shaped stenosis. Blood flow is modelled as homogeneous incompressible couple stress fluid. Further the effects of velocity slip at the arterial wall are also examined. The analysis is carried out analytically and closed form solutions are obtained with the assumption of mild stenosis. In the present study, we analyze the effects of various fluid and geometric parameters on the physiological parameters such as resistance to flow and shear stress at the wall. The variation in the resistance to the flow and wall shear stress with respect to stenosis size (∊,ψ), radius of the catheter (Rc), couple stress fluid parameters (β,ω), Reynolds number (Re) and pulsatile parameter (σ) has been studied. In particular shear stress at the wall is reckoned at both the locations corresponding to the maximum height of the stenosis. It has been observed that this physiological parameter is independent of the location of the maximum height in case of nontapered artery while these locations significantly impact the shear stress at the wall in case of tapered artery. The locations of the critical and maximum heights with corresponding annular radii are summarized in the form of Table 1. We also focussed our attention on the analysis of the wall shear stress over the entire stenosis region for various values of the geometric and fluid parameters. It is observed that the impedance and wall shear stress are increasing with increase in the radius of catheter and stenosis size while they are decreasing as the tapered parameter and the couple stress fluid parameters are increasing. It is observed that slip velocity and diverging tapered artery facilitate the fluid flow.

Citation

ID: 259746
Ref Key: srikanth2015ainunsteady
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
259746
Unique Identifier:
10.1016/j.asej.2015.01.003
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet