unilateral lag-screw technique for an isolated anterior 1/4 atlas fracture

unilateral lag-screw technique for an isolated anterior 1/4 atlas fracture

;Semih Keskil;Murat Göksel;Ulas Yüksel
journal of the chemical society, chemical communications 2016 Vol. 7 pp. 50-54
231
keskil2016journalunilateral

Abstract

Study Design: Fractures of the atlas are classified based on the fracture location and associated ligamentous injury. Among patients with atlas fractures treated using external immobilization, nonunion of the fracture could be seen. Objective: Ideally, treatment strategy for an unstable atlas fracture would involve limited fixation to maintain the fracture fragments in a reduced position without restricting the range of motion (ROM) of the atlantoaxial and atlantooccipital joints. Summary of Background Data: Such a result can be established using either transoral limited internal fixation or limited posterior lateral mass fixation. However, due to high infection risk and technical difficulty, posterior approaches are preferred but none of these techniques can fully address anterior 1/4 atlas fractures such as in this case. Materials and Methods: A novel open and direct technique in which a unilateral lag screw was placed to reduce and stabilize a progressively widening isolated right-sided anterior 1/4 single fracture of C 1 that was initially treated with a rigid cervical collar is described. Results: Radiological studies made after the surgery showed no implant failure, good cervical alignment, and good reduction with fusion of C 1 . Conclusions: It is suggested that isolated C 1 fractures can be surgically reduced and immobilized using a lateral compression screw to allow union and maintain both C 1-0 and C 1-2 motions, and in our knowledge this is the first description of the use of a lag screw to achieve reduction of distracted anterior 1/4 fracture fragments of the C1 from a posterior approach. This technique has the potential to become a valuable adjunct to the surgeon′s armamentarium, in our opinion, only for fractures with distracted or comminuted fragments whose alignment would not be expected to significantly change with classical lateral mass screw reduction.

Citation

ID: 259002
Ref Key: keskil2016journalunilateral
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
259002
Unique Identifier:
10.4103/0974-8237.176625
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet